Flame Retardant Coaxial Cables
Flame Retardant RG11 A/U Coaxial Cables
APPLICATION :
The cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.
STANDARDS:
Basic design adapted to MIL-C-17

FIRE PERFORMANCE:
| Flame Retardance (Single Vertical Wire Test)** | EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE 0482-332-1 ; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1* |
|---|---|
| Reduced Fire Propagation (Vertically-mounted bundled wires & cable test)** | EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4 |
Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
CABLE CONSTRUCTION :
Conductors: Tinned copper wire, stranded according to IEC(EN) 60228 class 2.
Insulation: Low density PE.
Overall Screen: Plain copper wire braid
Outer Sheath: Thermoplastic PVC compound. UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option. Compliance to fire performance standard (IEC 60332-1, IEC 60332-3, UL 1581, UL 1666 etc) depends on the oxygen index of the PVC compound and the overall cable design. LSPVC can also be provided upon request.
Physical AND THERMAL PROPERTIES:
Temperature Range During Operation (Fixed State): -30°C - +70°C
Temperature Range During Installation (Mobile State): -5°C - +60°C
Minimum Bending Radius: 8 X Overall Diameter
Electrical Properties:
| IMPEDANCE | 75±5Ω |
|---|---|
| CAPACITANCE | 67 NF/KM |
| Velocity ratio(%) | 66 |
| Insulation resistance | >2000 Mohm.Km |
| Shield coverage | 97% |
| DC resistance | |
| Inner conductor | 20.5 Ω/km |
| Outer conductor | 4.5 Ω/km |
Attenuation:
| Frequency(MHz) | Attenuation (dB/100 m) | Attenuation (dB/100ft) |
|---|---|---|
| 50 | 4.2 | 1.28 |
| 100 | 6.2 | 1.89 |
| 200 | 9.3 | 2.84 |
| 400 | 13.8 | 4.21 |
| 500 | 15.5 | 4.73 |
| 600 | 17.1 | 5.21 |
| 860 | 20.1 | 6.13 |
| 1000 | 23.4 | 7.13 |
Return Loss:
| Frequency(MHz) | Return Loss (dB) |
|---|---|
| 30-300 MHz | >30dB |
| 300-600 MHz | >27dB |
| 600-900 MHz | >25dB |
CONSTRUCTION PARAMETERS:
| Cable Code |
Conductor Diameter |
Nominal Insulation Diameter | Nominal Screen No.x Diameter |
Nominal Overall Diameter | Approx. Weight |
|---|---|---|---|---|---|
| mm | mm | No. x mm | mm | kg/km | |
| FGD RG11 A/U | 7 x 0.40 | 7.25 ± 0.18 | 192 x 0.18 | 10.3 ± 0.18 | 150 |