Customized Products
Fire Resistant CAT6A SWB Armoured Data Cables
Fire Resisting S/FTP Cat6A Cable to IEC 60331-23
part no. FFX-CAT6S/FTP4P23FR SWB


Application:
Cat6 Cable is a cable standard for Gigabit Ethernet and other network protocol, suitable for 10BaseT, 100BaseTx & 1000BaseT (Gigabit Ethernet) application. In addition, these cables can be offered with copper wire braid armoured & fame retardant outer sheath, providing additional mechanically protection still maintaining the fexibility of the cable.
STANDARDS:
Basic design adapted to EN 50173
FIRE PERFORMANCE£º
| Circuit Integrity | IEC 60331-23; BS 6387 CWZ (Optional) |
|---|---|
| Flame Retardance (Single vertical wire or cable test) | IEC 60332-1-2; EN 60332-1-2 |
| Reduced Fire Propagation (Vertically-mounted bundled wires & cables test) | IEC 60332-3-24; EN 60332-3-24 |
| Halogen Free | IEC 60754-1; EN 50267-2-1 |
| No Corrosive Gas Emission | IEC 60754-2; EN 50267-2-2 |
| Minimum Smoke Emission | IEC 61034-2; EN 61034-2 |
CABLE CONSTRUCTION£º
Conductors: 23AWG solid bare copper.
Insulation: HDPE+fire barrier insulation.
Twinning: Two coloured insulated conductors twisted together to form a pair.
Individual Shield: Every pair is separately shielded with polyester aluminum foil, which covers> 100% of twisted pair, tinned copper drain wire is outside the Aluminum side contact with the braiding.
Fire Barrier tape: Mica glass tape applied over each pair. Overall Shield: Tinned copper braiding, min. 60% coverage.
Inner Sheath: Thermoplastic LSZH compound, coloured black. Armouring: Steel wire braiding.
Outer Sheath: SHF mud. Halogen-free fame retardant thermosetting LSZH compound type LTS3 as per BS 7655-6.1, which is UV resistance, oil resistance, mud resistance.
PHYSICAL AND THERMAL PROPERTIES£º
Temperature range: -30°C - +75°C
Minimum bending radius during installation (mobile state): 8 x Overall Diameter
Minimum bending radius during operation (ixed state): 4 x Overall Diameter
ELECTRICAL PROPERTIES£º
| AWG |
|
23 |
|---|---|---|
| Nominal Conductor Diameter | mm |
0.58 |
| Maximum DC Resistance@20°C | O/100m |
9.38 |
| Maximum DCR Unbalance | % |
3 |
| Maximum Mutual Capacitance | pF/m |
5.8 |
| Maximum Capacitance Unbalance | pF/100m |
30 |
| Characteristic Impedance@1-100MHz | O |
100±15 |
| Maximum Propagation Delay Skew | ns/100m |
18 |
TRANSMISSION PROPERTIES£º
| FREQ MHz |
Attenuation dB/100m | NEXT dB |
PSNEXT dB |
ELFEXT dB/100m |
PSELFEXT dB/100m |
RL dB |
|---|---|---|---|---|---|---|
0.772 |
1.8 |
76.0 |
74.0 |
70.0 |
67.0 |
— |
1 |
2.0 |
74.3 |
72.3 |
67.8 |
64.8 |
20.0 |
4 |
3.8 |
65.3 |
63.3 |
55.7 |
52.7 |
23.0 |
8 |
5.3 |
60.8 |
58.8 |
49.7 |
46.7 |
24.5 |
10 |
6.0 |
59.3 |
57.3 |
47.8 |
44.8 |
25.0 |
16 |
7.6 |
56.3 |
54.3 |
43.7 |
40.7 |
25.0 |
20 |
8.5 |
54.8 |
52.8 |
41.7 |
38.7 |
25.0 |
25 |
9.5 |
53.3 |
51.3 |
39.8 |
36.8 |
24.3 |
31.25 |
10.7 |
51.9 |
49.9 |
37.9 |
34.9 |
23.6 |
62.5 |
15.4 |
47.4 |
45.4 |
31.8 |
28.8 |
21.5 |
100 |
19.8 |
44.3 |
42.3 |
27.8 |
24.8 |
20.1 |
155 |
25.2 |
41.5 |
39.5 |
23.9 |
20.9 |
18.8 |
200 |
29.0 |
39.8 |
37.8 |
21.7 |
18.7 |
18.0 |
250 |
32.8 |
38.3 |
36.3 |
19.8 |
16.8 |
17.3 |
CONSTRUCTION PARAMETERS£º
| Cable Code | Construction No. of Elements×No. of Cores in Element×Conductor Diameter |
Nominal Insulation Thickness | Nominal Inner Sheath Thickness | Nominal Outer Sheath Thickness | Approx. Overall Diameter | Nominal Weight |
|---|---|---|---|---|---|---|
| mm | mm | mm | mm | mm | kg/km | |
FFX-CAT6S/FTP4P23FR SWB |
4×2×0.58 |
0.45 |
0.9 |
1.1 |
20.0 |
530 |