Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Cables for Oil Industry

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)
Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Shipboard Cables(JIS)
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Industrial Cables  

Industrial Cables

H05VVH6-F/H07VVH6-F

Application and Description

The cables are used for applications with medium mechanical stresses and sharp bending in one place.
They are suitable for use in dry, damp and wet rooms as power and control cable, especially on hoisting
equipment, handling systems, machine tools, etc.

Standard and Approval

<HAR>HD 359 S3, BS EN 50214, DIN VDE 0281 part 404, IEC 60332-1, CSA C22.2 N° 49, UL 62, UL 62

Cable Construction

- Fine bare or tinned copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- PVC compound insulation T12 to VDE 0207 part 4
- Color coded to VDE-0293-308
- PVC compound outer jacket TM2 to VDE 0207 part 5

Technical Characteristics

-Working voltage:
      H05VVH6-F : 300/500 V
      H07VVH6-F: 450/700 V
-Test voltage:
      H05VVH6-F : 2 KV
      H07VVH6-F: 2.5 KV
-Bending radius: 10 × cable Ø
-Flexing temperature: - 5º C to + 70º C
-Static temperature :-40º C to +70º C
-Flame retardant: test class B according to VDE 0472 part 804, IEC 60332-1
-Insulation resistance: 20 MΩ x km

Industrial Cables

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Thickness of Sheath mm
Nominal Overall Diameter mm
Nominal Copper Weight kg/Km
H05VVH6-F
18(24/32)
4 x 0.75
1.2
0.6
4.2 x 12.6
29
90
18(24/32)
8x 0.75
1.2
0.6
4.2 x 23.2
58
175
18(24/32)
12x 0.75
1.2
0.6
4.2 x 33.8
86
260
18(24/32)
18x 0.75
1.2
0.6
4.2 x 50.2
130
380
18(24/32)
24x 0.75
1.2
0.6
4.2 x 65.6
172
490
17(32/32)
4 x 1.00
1.4
0.7
4.4 x 13.4
38
105
17(32/32)
5×1.00
1.4
0.7
4.4 x 15.5
48
120
17(32/32)
8 x 1.00
1.4
0.7
4.4 x 24.8
77
205
17(32/32)
12x 1.00
1.4
0.7
4.4 x 36.2
115
300
17(32/32)
18x 1.00
1.4
0.7
4.4 x 53.8
208
45
17(32/32)
24x 1.00
1.4
0.7
4.4 x 70.4
230
590
H07VVH6-F
16(30/30)
4 x1.5
1.5
0.8
5.1 x 14.8
130
58
16(30/30)
5 x1.5
1.5
0.8
5.1 x 17.7
158
72
16(30/30)
7 x1.5
1.5
0.8
5.1 x 25.2
223
101
16(30/30)
8 x1.5
1.5
0.8
5.1 x 27.3
245
115
16(30/30)
10 x1.5
1.5
0.8
5.1 x 33.9
304
144
16(30/30)
12 x1.5
1.5
0.8
5.1 x 40.5
365
173
16(30/30)
18 x1.5
1.5
0.8
6.1 x 61.4
628
259
16(30/30)
24 x1.5
1.5
0.8
5.1 x 83.0
820
346
14(30/50)
4 x2.5
1.9
0.8
5.8 x 18.1
192
96
14(30/50)
5 x2.5
1.9
0.8
5.8 x 21.6
248
120
14(30/50)
7 x2.5
1.9
0.8
5.8 x 31.7
336
168
14(30/50)
8 x2.5
1.9
0.8
5.8 x 33.7
368
192
14(30/50)
10 x2.5
1.9
0.8
5.8 x 42.6
515
240
14(30/50)
12 x2.5
1.9
0.8
5.8 x 49.5
545
288
14(30/50)
24 x2.5
1.9
0.8
5.8 x 102.0
1220
480
12(56/28)
4 x4
2.5
0.8
6.7 x 20.1
154
271
12(56/28)
5 x4
2.5
0.8
6.9 x 26.0
192
280
12(56/28)
7 x4
2.5
0.8
6.7 x 35.5
269
475
10(84/28)
4 x6
3.0
0.8
7.2 x 22.4
230
359
10(84/28)
5 x6
3.0
0.8
7.4 x 31.0
288
530
10(84/28)
7 x6
3.0
0.8
7.4 x 43.0
403
750
8(80/26)
4 x10
4.0
1.0
9.2 x 28.7
384
707
8(80/26)
5 x10
4.0
1.0
11.0 x 37.5
480
1120
6(128/26)
4 x16
5.6
1.0
11.1 x 35.1
614
838
6(128/26)
5 x16
5.6
1.0
11.2 x 43.5
768
1180