Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Cables for Oil Industry

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)
Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
NEK606 Offshore & Marine Cable
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Shipboard Cables(JIS)
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
En 50288-7 Cable
NF M 87-202

 
 
  Industrial Cables  

Industrial Cables - Single Core Fixed Wiring Cable

6181B to BS 7889

Application and Description

These cables are designed for fixed wiring purposes in domestic and industrial power/lighting applications. They can be installed in trunking or conduit, or may be surface mounted when used for earthing. They are suitable for use in areas (such as public and government buildings) where smoke and toxic fumes may cause a threat to life and equipment. When mechanical protection is required, they can be embedded in concrete.

Cable Construction

- Bare copper made of strands conductor
- Stranding to IEC 60228 Class 2
- XLPE insulation
- LSOH sheath

Industrial Cables 6181B to BS 7889

Core Identification

Black, Blue, Brown

Technical Characteristics

- Working voltage: 600/1000 volts
- Minimum bending radius: up to 25 mm² - 4xoverall diameter,
above 25 mm² - 6xoverall diameter
- Operating temperature: -15º C to +90º C
- Insulation resistance: 10 MΩxkm
- Halogen free acc. to EN 50267-2-1 / IEC 60754-1
- Smoke density acc. to EN 50268-2 / IEC 61034-2
- Corrosivity of gases acc. to EN 50267-2-2, IEC 60754-2
- Flame retardancy acc. to EN 50265-2-1, IEC 60332-1

Cable Parameter

AWG
(No of Strands/
Strand
Diameter)

No. of Cores  x Nominal Cross Sectional Area
#xmm²

Nominal
Thickness
of Insulation
mm

Nominal Thickness of Sheath
mm

Nominal Overall Diameter
mm

Nominal Weight kg/km

16(1/16)

1x1.5

0.7

1.4

6

50

14(1/14)

1x2.5

0.7

1.4

6.5

70

12(7/20)

1x4

0.7

1.4

7

80

10(7/18)

1x6

0.7

1.4

7.5

110

8(7/16)

1x10

0.7

1.4

8.5

150

6(7/14)

1x16

0.7

1.4

9.5

215

4(7/12)

1x25

0.9

1.4

11.5

315

2(7/10)

1x35

0.9

1.4

12

415

1(19/13)

1x50

1

1.4

13

555

2/0(19/11)

1x70

1.1

1.4

15

760

3/0(19/10)

1x95

1.1

1.5

17

1025

4/0(37/12)

1x120

1.2

1.5

18.5

1270

300MCM(37/11)

1x150

1.4

1.6

21.5

1575

350MCM(37/10)

1x185

1.6

1.6

23

1955

500MCM(61/11)

1x240

1.7

1.7

26

2470

-(61/10)

1x300

1.8

1.8

28

3155

-(61/9)

1x400

2

1.9

32

4049

-(61/8)

1x500

2.2

2

36

5100

-(127/10)

1x630

2.4

2.2

40

6410