Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL,GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
    Fiber Optic Cables  
 

Fiber Optic Cables

    Application

The “All Dielectric Self-supporting (ADSS)” cable is designed for aerial self supporting application at short, medium and long span distances. ADSS cable offers a rapid and economical means for deployment by cable television operators, telephone companies and power utilities. It is adopted for high voltage, middle, small span conditions in Power Transmission System or mazy terrain such as river spanning, mountains.

    Description

The cable consists of 5 to 36 fi bers containing tubes or fi llers stranded in up to 3 layers around a central strength member and bound under a PE jacket. Each tube contains 6 -12 fi bers. All the fi bers in the cores are fi lled with water blocking gel. Fillers may be used to preserve the cable geometry. A water swelling tape is helically wrapped around the cable core. Aramid yarns are helically laid to supply peripheral strengthening of the cable. The outer jacket is tightly bounded over the aramid yarn layer. The cable jacket incorporates an optional inner polyethylene jacket and an outer polyethylene or AT (anti-tracking) jacket. When the induction on cable surface is above 12KV, anti-tracking sheath material (AT) will be applied. With AT outer jacket, the maximum electric fi eld strength at operating point can reach 35KV. For long span application, a double jacket design can be considered. An optional ripcord can be put under the jacket layer to faciliate its removal.

    Construction

Fiber Optic Cable
Fiber Optic Cable

    Physical Properties

Span(m)

Ice+Wind:0mm+35m/sec

Ice+Wind:12mm+30m/sec

Cable O.D.(mm/in)

Cable Weight(kg/km)/(lb/kft)

Max.Working Tension(N/lb)

Max
.Sag(%)

Cable O.D.(mm/in)

Cable Weight(kg/km)/(lb/kft)

Max.Working Tension(N/lb)

Max
.Sag(%)

100

13.9/5.472

152/102.01

7578/1704

2

13.8/0.543

150.0/100.67

6621/1489

2

200

14.3/0.562

161/108.05

10430/2346

3

14.1/0.555

157.0/105.37

9000/2024

3

400

15.9/0.625

199/133.56

23221/5223

3

15.4/0.606

187.0/125.50

19225/4331

3

500

16.7/0.657

220/147.65

30590/6881

3

16.1/0.633

204.0/136.91

24885/5598

3

600

16.3/0.641

209/140.27

26952/6063

4

15.7/0.618

196.0/131.54

22154/4983

4

800

16.5/0.649

216/144.97

29452/6625

5

15.9/0.625

201.0/134.90

24042/5408

6

1000

16.7/0.657

221/148.32

31271/7034

6

16.1/0.633

204.0/136.91

24407/5490

6

* Above table do not cover all of available types. Other ADSS cables can be manufactured upon customer's request according to different span and sag environment.

   Mechanical Properties

Minimum Bending Radius:   Maximum Compressive Load: 4000N
Under installation: 20×OD Repeated Impact: 4.4 N.m (J)
During operation 10×OD for unarmoured cables Twist (Torsion): 180×10 times, 125×OD
  20×OD for armoured cables Cyclic Flexing: 100 cycles
Temperature Range:      
Operating Temperature Range: -40℃(-40℉) to +70℃(+158℉) Crush Resistance: 263N/cm (1250lb/in)
Storage Temperature Range: -50℃(-58℉) to +70℃(+158℉)    

   Fiber Compliance

Temperature Cycling
Tensile Strength
Crush
Impact
Repeated Bending
Torsion
Kink
Cable Bend
Cool Bend

IEC60794-1-2-F2
IEC60794-1-2-E1A
IEC60794-1-2-E3
IEC60794-1-2-E4
IEC60794-1-2-E6
IEC60794-1-2-E7
IEC60794-1-2-E10
IEC60794-1-2-E11
IEC60794-1-2-E11

  
   Standard Compliance

        Telcordia GR-20          RUS 7 CFR 1755.900 (REA PE-90)                         ICEA S 87-640                 IEEE1222

   Features

• High capacity cable offer great flexibility for placement on overhead transmission towers, eliminating the need for a support messenger.
• Dry core design and high tension strength capability suitable for toughest environmental and electrical conditions.
• Fit for extra high voltage power lines without interruption of power service to the customers.
• Typical spans with 1%-1.5% installation sag