Airport Cable  
 

 CCTV (Closed Circuit TV)
RS485 Data Cable RE-02Y(St)H 1P18A
RE-02Y(St)H 1P18A (CU/PE/OSCR/LSZH 1×2×18AWG)

RS485 Data Cable RE-02Y(St)H 1P18A    

Applications

Airprot cables are designed for RS485 data connections. Airprot cable combines low capacitance insulation with one of the highest levels of screening to provide high speed, interference free, data transmission where continued functionality is required during a fire situation.

Standards

Basic design EIA/TIA 485
Halogen Free IEC 60754-1
No corrosive gas emission IEC 60754-2
Minimum Smoke Emission IEC 61034-1/2
Reduced Fire Propagation IEC 60332-3C / NF C 32070-2.2 (C1)
Flame Retardance IEC 60332-1 / NF C 32-070-2.1 (C2)
Fire Resistance IEC 60331-23 / NF C 32-070-2.3(CR1)

Construction

Conductors: tinned annealed copper wire, stranded according to IEC(EN) 60228 class 2 or class 5.
Insulation: Solid or foam PE compound
Cabling Elements: Insulated cores are twisted to form pairs with varying lay length to minimize crosstalk.
Overall screen: Aluminum/ polyester tape with tinned copper drain wire.
Fire Barrier: Fireproof Tape
Outer Sheath: Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1.

Electrical PROPERTIES
Dielectric test 1000 V r.m.s. for 5’ (core-core)
  1000 V r.m.s. for 5’ (core-screen)
Impedance 120Ω
Capacitance 45 nF/km conductor to conductor
  90 nF/km conductor to shield

CONSTRUCTION PARAMETERS

No.of pair × Wire
Gange
Number &
Nominal Diameter of Strands
Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Approx. Weight
AWG No/mm mm mm mm kg/km
1 18 7/0.404 1.15 1.2 10.5 100
1 18 16/0.254 1.15 1.2 10.5 100