Airport Cable  
 

 RG 6/U

RG59 B/U

APPLICATION
Airprot cables are designed for CCTV, security, smoke detection and evacuation monitoring applications, where continued functionality is required during a fire situation. Due to the zero halogen low smoke construction, this cable is ideal for use in public, commercial and industrial environments.
STANDARDS
Basic design to MIL-C-17
FIRE PERFORMANCE

FlameRetardance (SingleVerticalWireTest)** EN60332-1-2; IEC60332-1-2; BSEN 60332-1-2; VDE0482-332-1; NBN C30-004 (cat.F1);NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*
Reduced FirePropagation(Vertically-mountedbundledwires &cabletest)** EN60332-3-24(cat.C); IEC60332-3-24;BSEN60332-3-24;VDE0482-332-3;NBN C30-004 (cat.F2);NF C32-070-2.2(C1);CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4

Note:
Asterisk * denotes superseded standard
Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC
compound and the cable design.
CABLE CONSTRUCTION
Conductors: Copper clad steel
Insulation: Foam PE compound.
Screen 1: Aluminium foil
Screen 2: Aluminium wire braid
Outer Sheath: Thermoplastic PVC compound.
Physical AND THERMAL PROPERTIES
Temperature range during operation (fixed state): -30°C - +70°C
Temperature range during installation (mobile state): -5ºC - +60ºC
Minimum bending radius: 8 x Overall Diameter

Electrical Properties

Impedance 75±5Ω
Capacitance 54NF/kM
Velocityratio(%) 82
Insulationresistance >5000Mohm.km
Shieldcoverage 70%
DC resistance  
Innerconductor 23.1Ω/km
Outerconductor 31 Ω/km

Attenuation

Frequency(MHz) Attenuation(dB/100m) Attenuation(dB/100ft)
50 5.0 1.5
100 6.4 1.96
200 9.2 2.8
500 14.5 4.4
600 15.9 4.9
800 17.7 5.4
1000 21.9 6.7
1350 24.9 7.6
1750 29.0 8.8
2050 33.1 10.1
2400 36.4 11.1

CONSTRUCTION PARAMETERS

CableCode ConductorDiameter NominalInsulation Diameter NominalScreen No.xDiameter NominalOverall Diameter Approx. Weight
  mm mm No. x mm mm kg/km
RG6/U 1.02 4.8 96*×0.12 7.0 43