| Windmill Cables | |||
| EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable | HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable | Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ | more |
Windmill Cables
UL/CSA 600V PVC/PVC Screened Torsion Resistant Cable
Application
UL/CSA 600V PVC/PVC Screened Torsion Resistant Cables with increased tolerance to torsion application, UV
and oil resistant are specifically designed for wind power applications.
Standards
UL 758
Construction

Conductor:Stranded bare copper according to DIN VDE 0295.
Insulation: Special PVCflexible at low temperatures.
Screen: Tinned copper wire wrapped.
Sheath: Special PVCflexible at low temperatures.
Technical Data
Rated Voltage U0/U (Um):1000V
Operating Temperatures:-40℃~+80℃
Minimum Bending Radius:10×OD
Torsion Application:+/-90°/m
Flame Retardant:FT1
Oil Resistant:Yes
UV Resistant:Yes
Dimensions and Weight
| Construction | AWG /MCM | Nominal Overall Diameter | Nominal Weight |
|---|---|---|---|
| No. of cores×mm² | - | mm | kg/km |
| 2×2×0.25 | 24 | 8.9 | 90 |
| 4×2×0.25 | 24 | 9.9 | 115 |
| 5×2×0.25 | 24 | 11.1 | 130 |
| 4×0.34 | 22 | 7.7 | 91 |
| 2×2×0.34 | 22 | 9.6 | 110 |
| 4×2×0.34 | 22 | 11.0 | 130 |
| 4×0.5 | 20 | 8.0 | 105 |
| 6×0.5 | 20 | 9.2 | 130 |
| 10×0.5 | 20 | 11.4 | 170 |
| 12×0.5 | 20 | 11.7 | 220 |
| 2×2×0.5 | 20 | 9.8 | 115 |
| 4×2×0.5 | 20 | 11.3 | 150 |
| 3×0.75 | 19 | 7.7 | 97 |
| 4×0.75 | 19 | 8.3 | 122 |
| 5×0.75 | 19 | 9.0 | 145 |
| 7×0.75 | 19 | 9.7 | 200 |
| 8×0.75 | 19 | 10.7 | 220 |
| 12×0.75 | 19 | 12.2 | 258 |
| 18×0.75 | 19 | 14.4 | 400 |
| 25×0.75 | 19 | 17.8 | 552 |
| 32×0.75 | 19 | 18.8 | 610 |
| 41×0.75 | 19 | 21.2 | 795 |
| 50×0.75 | 19 | 23.5 | 900 |
| 2×2×0.75 | 19 | 10.4 | 130 |
| 4×2×0.75 | 19 | 12.7 | 211 |
| 8×2×0.75 | 19 | 17.1 | 410 |
| 12×2×0.75 | 19 | 17.6 | 520 |
| 4×1.0 | 18 | 8.7 | 110 |
| 6×1.0 | 18 | 10.2 | 150 |
| 8×1.0 | 18 | 11.7 | 210 |
| 12×1.0 | 18 | 13.3 | 280 |
| 2×1.5 | 16 | 6.8 | 86 |
| 3×1.5 | 16 | 8.8 | 133 |
| 4×1.5 | 16 | 9.4 | 159 |
| 5×1.5 | 16 | 10.3 | 195 |
| 7×1.5 | 16 | 11.9 | 247 |
| 12×1.5 | 16 | 14.7 | 410 |
| 2×2×1.5 | 16 | 12.1 | 180 |
| 3×2×1.5 | 16 | 14.0 | 235 |
| 4×2×1.5 | 16 | 14.6 | 210 |
| 3×2.5 | 14 | 10.4 | 210 |
| 4×2.5 | 14 | 10.6 | 264 |
| 5×2.5 | 14 | 12.3 | 288 |
| 7×2.5 | 14 | 14.8 | 411 |
| 12×2.5 | 14 | 18.2 | 638 |
| 5×4 | 12 | 13.6 | 382 |
| 7×4 | 12 | 16.3 | 582 |
| 12×4 | 12 | 20.0 | 806 |
| 5×6 | 10 | 17.4 | 640 |
| 4×10 | 8 | 17.8 | 727 |
| 5×10 | 8 | 19.8 | 935 |
| 4×16 | 6 | 21.1 | 1072 |
| 5×16 | 6 | 26.2 | 1330 |
| 4×25 | 4 | 26.0 | 1664 |
| 5×25 | 4 | 28.6 | 2014 |
| 4×50 | 1 | 37.0 | 3200 |
| 1×70 | 2/0 | 19.8 | 950 |
| 1×95 | 3/0 | 22.5 | 1200 |
| 1×120 | 4/0 | 25.0 | 1400 |
| 1×150 | 300 | 24.9 | 2000 |
| 1×185 | 350 | 27.8 | 2340 |
| 1×240 | 500 | 32.5 | 3150 |
| 1×300 | 600 | 39.0 | 3920 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information