Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable HFEPR/HFEVA 0.6/1kV LSOH Screened Torsion Resistant Power Cable Al Conductor EPR/XLEVA 0.6/1kV LSOH Power Cable 90℃ more

  Windmill Cables

LSOH Screened Torsion Resistant Loop Cable 0.6/1kV

Windmill Cables

Application

These cables are designed for special application condition in wind turbines, special for medium mechanical

stress and for operation under permanent influence of seawater and usage outdoor.

Standards

IEC 60502

EN 50363

HD 22.13

Construction

Conductor: Stranded bare copper conductor.

Insulation: Extruded halogen free rubber compound EI8.

Screen: Tinned wire copper braid.

Sheath: Extruded halogen free EVA compound EM8.

Technical Data

Rated Voltage Uo/U (Um) 0.6/1 kV
Operating Temperatures flexing: -35℃~+90℃; fixed installation: -40℃~+90℃
Minimum Bending Radii fixed: 4×OD; flexing: 6×OD
Torsion Application ± 100 °/m
Maximum Permissible Tensile Load 15 N/mm² (in operation)
Short-circuit Temperature 250℃
Flame Retardant EN 50265-2-1
Halogen Free IEC 60754
Smoke Density IEC 61034
Oil Resistant Yes
Ozone Resistant Yes
Silicone Free Yes

Dimensions and Weight

Construction Nominal Overall Diameter Nominal Weight
No. of cores×mm² mm kg/km
25×0.75 18.0 500
25×1 20.0 550
4×1.5 10.0 150
12×1.5 16.0 400
32×1.5 26.0 950
42×1.5 35.0 1700
12×2.5 23.0 620
5×2.5 15.0 300
4×4 13.5 300