Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Windmill Cables
EPR/HFXLEVA LSOH 0.6/1kV Torsion Resistant Power Cable

  Windmill Cables

(N)TSCGEHXOEU Medium Voltage LSOH Torsion Resistant Cable

Application

These LSOH cables are specifically designed for special application condition in wind turbines, used for economical transmission of large energy rates with medium voltage.

Standards

DIN VDE 0250 Part 813

Construction

Conductor: Stranded tinned/bare copper, class 5 according to DIN VDE 0295 IEC 60228.
Inner Conductor Layer:Semiconductive halogen free rubber compound.
Insulation: Halogen free, heat resistant insulation based on EPR.
Outer Conductor Layer: Semiconductive rubber compound.
Optional Inner Sheath: Extruded special rubber compound.
Sheath: Halogen free special rubber compound based on EVA.

Technical Data

Rated Voltage Uo/U (Um)

8.7/15 kV, 12/20 kV,18/30 kV,20/35 kV

Operating Temperatures

-40℃~+90℃

Minimum Bending Radius

10×OD

Torsion Application

+/100°/m

Maximum Permissible Tensile Load

15N/mm²

Short-circuit Temperature

250℃

Flame Retardant

DIN EN 60332-1

Halogen Free

IEC 60754

Corrosive Gases

DIN EN 50267-2-3

Smoke Density

DIN EN 50268-2

Oil Resistant

Yes

Ozone Resistant

Yes

UV Resistant

Yes

Silicone Free

Yes

Dimensions and Weight

8.7/15kV

Construction

Nominal Overall Diameter

Nominal Weight

No. of cores×mm²

mm

kg/km

3×50/50

51.5

4050

3×70/70

57.5

5250

3×95+3×16.7

57.5

5600

12/20kV

Construction

Nominal Overall Diameter

Nominal Weight

No. of cores×mm²

mm

kg/km

3×25/25

51.5

3400

3×35/35

54.5

4000

3×50/50

56.5

4700

3×70/70

59.0

5700

3×95/95

65.5

6900

18/30kV

Construction

Nominal Overall Diameter

Nominal Weight

No. of cores×mm²

mm

kg/km

3×25/25

67.5

5300

3×35/35

67.5

5600

3×50/50

69.5

6300

3×70/70

71.5

7100

3×95/95

76.5

8500

20/35 kV

Construction

Nominal Overall Diameter

Nominal Weight

No. of cores×mm²

mm

kg/km

3×25/25

73.0

6100

3×35/35

73.0

6500

3×50/50

73.0

6800

3×70/70

76.0

7900

3×95/95

78.0

9100