VG 95218 Navy Cables

     

 VG 95218 Navy Cables

MGGO & MGSGO ships power cables acc. to VG 95218 part 60

Application

These cables are designed for fixed installation in electrial power and control systems below and above deck,

preferably on ships of the German Navy and/or German design of construction. Not intended for permanent

installation in or under water. Fulfill all requirements of BV3400 (Specification for Construction of German Navy

vessels).

Standards

VG 95218-60

VG 95218-2

IEC 60228

DIN VDE 0207-20(VDE 0207 part 20) 

Construction

Conductor: Bare copper conductor, stranded class 2 or class 5 

Insulation: crosslinked EPR

Filling compound

Screen (for MGSGO type): Bare copper wire braided screen, separator tape (optional) 

Sheath: crosslinked elastomer compound, black.

Electrical and mechanical characteristics 

Nominal Voltage: Uo/U = 0.6 / 1 kV

Max. operating voltage: AC 1,200 V DC 1,800 V

Operating temperature at conductor: + 85 °C

Dimensions and Weight

MGSGO TYPE A

NOMENCLATURE ACC. VG 95218 PART 60 TYPE/PART NO.

NUMBER OF CORES AND NOMINAL CROSS SECTION MM²

NOMINAL DIAMETER OF CONDUCTOR 
MM

NOMINAL INSULATION THICKNESS 
MM

NOMINAL SHEATH THICKNESS
MM

OUTER DIAMETERS MIN. /MAX. MM

CABLE WEIGHT KG/KM

A001

1x4

2.7

1.0

1.0

7.5

8.5

150

A002

1x6

3.3

1.0

1.0

8.4

9.4

180

A003

1x10

4.2

1.0

1.1

9.5

10.5

240

A004

1x16

5.3

1.0

1.1

10.0

11.0

255

A005

1x25

6.6

1.2

1.2

12.0

13.0

415

A006

1x35

7.9

1.2

1.2

13.0

14.0

525

A007

1x50

9.1

1.4

1.3

15.0

16.0

675

A008

1x70

11

1.4

1.3

17.0

18.0

885

A009

1x95

12.9

1.6

1.4

19.5

20.5

1190

A010

1x120

14.5

1.6

1.4

21.0

22.4

1330

A011

1x150

16.2

1.8

1.5

23.0

24.4

1760

A012

1x185

18

2.0

1.6

25.5

27.0

2170

A013

1x240

20.6

2.2

1.7

29.0

30.5

2600

A014

1x300

23.1

2.4

1.8

31.5

33.5

3240

A015

1x185

18.1

2.0

1.6

26.2

27.7

2192

MGSGO TYPE B

NOMENCLATURE ACC. VG 95218 PART 60 TYPE/PART NO.

NUMBER OF CORES AND NOMINAL CROSS SECTION MM²

NOMINAL DIAMETER OF CONDUCTOR MM

NOMINAL INSULATION THICKNESS

NOMINAL SHEATH THICKNESS MM

OUTER DIAMETERS MIN. /MAX. MM

CABLE WEIGHT KG/KM

B001

2x1.5

1.7

1.0

1.2

11.5

12.5

238

B002

2x2.5

2.2

1.0

1.2

12.4

13.4

284

B003

2x4

2.7

1.0

1.2

13.4

14.7

340

B004

2x6

3.3

1.0

1.3

14.7

16.0

436

B005

2x10

4.2

1.0

1.3

16.2

17.7

565

B006

2x16

5.3

1.0

1.4

19.0

20.3

776

B007

2x25

6.6

1.2

1.5

22.5

24.0

1,063

B008

3x1.5

1.7

1.0

1.2

12.0

13.0

255

B009

3x2.5

2.2

1.0

1.2

13.0

14.2

321

B010

3x4

2.7

1.0

1.2

14.0

15.2

414

B011

3x6

3.3

1.0

1.3

15.5

16.8

526

B012

3x10

4.2

1.0

1.4

17.6

18.9

730

B013

3x16

5.3

1.0

1.4

20.0

21.4

1,080

B014

3x25

6.6

1.0

1.6

24.0

25.4

1,330

B015

3x35

7.9

1.0

1.7

26.0

28.2

1,780

B016

3x50

9.1

1.0

1.8

30.0

32.2

2,180

B017

3x70

11

1.2

1.9

34.5

36.7

2,985

B018

3x95

12.9

1.2

2.1

39.7

42.2

4,210

B019

3x120

14.5

1.2

2.2

43.0

45.7

5,080

B020

4x4

2.7

1.0

1.3

15.2

16.5

470

B021

4x6

3.3

1.0

1.3

17.0

18.3

660

B022

4x10

4.2

1.0

1.4

19.4

20.9

900

B023

4x16

5.3

1.0

1.5

22.0

23.5

1,150

B024

4x25

6.6

1.0

1.7

26.4

28.0

1,670

B025

4x35

7.9

1.0

1.8

29.2

31.0

2,155

B026

4x50

9.1

1.2

1.9

33.5

35.8

2,755

B027

4x70

11

1.2

2.1

38.2

40.7

3,740

B028

4x95

12.9

1.2

2.3

44.2

46.7

4,980

B029

19x6

3.2

0.7

1.8

29.4

31.2

2000

B030

33x0.75

1.2

0.8

1.4

22.5

24.5

850

B031

3x95

13.0

1.6

2.1

41.6

43.8

4300


MGGO TYPE C

NOMENCLATURE ACC. VG 95218 PART 60 TYPE/PART NO.

NUMBER OF CORES AND NOMINAL CROSS SECTION MM²

NOMINAL DIAMETER OF CONDUCTOR MM

NOMINAL INSULATION THICKNESS

NOMINAL SHEATH THICKNESS MM

OUTER DIAMETERS MIN. /MAX. MM

CABLE WEIGHT KG/KM 

C001

1x150

15.5

1.8

1.5

21.5

24

1600

C002

1x185

18.1

2.0

1.6

24.8

26.3

2192