Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Cables for Oil Industry

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)
Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
NEK606 Offshore & Marine Cable
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Shipboard Cables(JIS)
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
En 50288-7 Cable
NF M 87-202

 
 
  Telephone Cables

 PE/PVC Insulated Parallel Drop Wires to RUS (REA) PE-7

Application

The drop wires are designed for use in extending telephone circuits to subscriber premises by means of an aerial drop from distribution wire or cables. The shape may be in oval/dumbbell shape to aid in separation of conductors.

Standards

• RUS (REA) PE-7

• ASTM B227, B452 & B1

Construction

Telephone Cables

Telephone Cables

Conductors
Two conductors made of 0.9/1.0/1.023mm copper covered steel wires serve dually as conductor and strength members

Bonding
Bonding of the insulation to the conductors is made to assure the full conductor strength is transferred to the wire support clamps

Insulation
Conductors are laid in a parallel configuration and covered with low density or medium density polyethylene (PE) or polyvinyl chloride (PVC)

Electrical Properties

Nominal Conductor Diameter

mm

0.9

1.0

1.023

Conductor Gauge Size

AWG

19

18.5

18

Conductor Size

mm2

0.636

0.785

0.827

Minimum Insulation Resistance @500V DC

MΩ.km / MΩ.kft

30/100

30/100

30/100

Dielectric Strength Conductor to Conductor(3secs)

V DC

7050

7050

7050

Nominal Insulation Thickness

mm/inch

1.02/0.039

1.02/0.039

1.02/0.039

Nominal Insulated Conductor Diameter

mm/inch

2.94/0.116

3.04/0.117

3.06/0.118

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 7.5 x Overall Diameter

Dimensions And Weight

Cable Code Number of
Cores
Insulation
Material
Nominal Insulation Thickness
mm/inch
Nominal Overall Dimensions
mm/inch
Nominal Weight
kg/km / lbs/kft
1.023mm Conductor, 3.06 Insulated Wire

TP7-2Y-1P18A-SS

2

PE

1.02/0.04

3.0x7.0/0.11x0.28

32/22

TP7-Y-1P18A-SS

2

PVC

1.45/0.06

3.9x7.6/0.15x0.30

49/33

1.0mm Conductor, 3.04 Insulated Wire
TP7-Y-1P18/5A-SS 2 PVC 1.02/0.04 3.9x7.4/0.15x0.29 46/31
0.9mm Conductor, 2.94 Insulated Wire
TP7-2Y-1P19A-SS 2 PE 1.02/0.04 2.9x7.7/0.11x0.30 25/17