Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Telephone Cables

 Drop Wires No. 1, 2, 6 & 8 to CW 1166, CW 208, CW 1247 & CW1320A

Application

The drop wires are designed for extending an open wire line or distribution pairs from a pole or cable terminal to a building. The drop wires are to be installed between distribution point and telephone subscriber premises.

Standards

• CW 1166 (Drop Wires No. 1)

• CW 208 (Drop Wires No. 2)

• CW 1247 (Drop Wires No. 6)

• CW 1320A (Drop Wires No. 8)

Construction

Conductors
Solid cadmium copper of 0.91mm to BS 4807 (Drop Wires No. 1)
Solid copper covered steel of 0.71mm to BS 4807 (Drop Wires No. 2)
Solid copper covered steel of 0.81mm to BS 4807 (Drop Wires No. 6)
Solid cadmium copper of 1.14mm to BS 4807 (Drop Wires No. 8)

Insulation
PVC to BS 6746 T1 (Drop Wires No. 1)
PVC to BS 6746 T2 (Drop Wires No. 2)
PVC to BS 7878 T1 (Drop Wires No. 6)
PVC to BS 6746 T1 (Drop Wires No. 8)

Cable Core Assembly
Two conductors are extruded parallel, figure-8 type

Electrical Properties

Nominal Conductor Diameter

mm

0.91

0.71

0.81

1.14

BT Drop Wire Reference

 

No. 1 No.2 No.6

No. 8

Conductor Size

mm2

0.65 0.4 0.52

1.02

Minimum Insulation Resistance @500V DC

MΩ.km

24 24 50

24

Minimum Insulation Thickness

mm

0.75 1.02 0.8

1.52

Nominal Insulated Conductor Diameter

mm

2.41 2.75 2.41

4.18

Mechanical and Thermal Properties

Temperature range during operation (fixed state): -30°C – +70°C
Temperature range during installation (mobile state): -20°C – +50°C
Minimum bending radius: 10 x Overall Diameter

Dimensions And Weight

Cable Code

Number of
Cores

Minimum Insulation
Thickness mm

Maximum Cable Dimensions
Diameter X Height
mm

Nominal Weight kg/km

0.91mm Conductor, 2.41mm Insulated Wire
TP1166-Y-1P091-DW1 2 0.75 2.7x5.6 25
0.71mm Conductor, 2.75mm Insulated Wire
TP208-Y-1P071-DW2 2 1.02 2.75x6.0 20
0.81mm Conductor, 2.41mm Insulated Wire
TP1247-Y-1P081-DW6 2 0.8 2.5x5.4 23
1.14mm Conductor, 4.18mm Insulated Wire
TP1320A-Y-1P114-DW8 2 1.52 4.44x9.4 34