Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Cables for Oil Industry

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)
Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
NEK606 Offshore & Marine Cable
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Shipboard Cables(JIS)
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
En 50288-7 Cable
NF M 87-202

 
 
  Submarine Cables

Submarine Cables

XLPE Insulated AC Medium-voltage Submarine Cable


Applications

These submarine cables are used for power transmission to offshore islands, oil platforms or to cross-rivers and lakes. Cable design based on the mayor national or international standards e.g. VDE, IEC and ICEA or according to customers design and standards.

Construction

Submarine Cables

  • Conductor:Copper conductor, circular stranded compacted, water blocked.
  • Conductor Screening: Extruded semi-conductive compound.
  • Insulation: XLPE.
  • Insulation Screening: Extruded semi-conductive compound.
  • Screen: Copper tapes.
  • Separator: Plastic foil.
  • Core Sheath: PE.
  • Fillers: Polypropylene filler.
  • Separator: Binder tapes
  • Bedding Layer: Polypropylene strings.
  • Armour: Galvanized steel wires.
  • Serving: Hessian tapes, bituminous compound, polypropylene strings.

Electrical Data:

6/10(12) kV

Nominal Cross Section Area

Capacitance

Inductance

Current Rating

mm²

μF/mm

mH/km

A

35

0.23

0.41

166

50

0.26

0.39

196

70

0.29

0.37

240

95

0.32

0.35

287

120

0.35

0.34

325

150

0.38

0.33

364

185

0.42

0.32

408

240

0.47

0.30

471

12/20(24) kV

Nominal Cross Section Area

Capacitance

Inductance

Current Rating

mm²

μF/mm

mH/km

A

35

0.17

0.45

168

50

0.18

0.43

199

70

0.20

0.40

243

95

0.22

0.38

290

120

0.24

0.37

329

150

0.26

0.35

368

185

0.28

0.34

412

240

0.31

0.33

472

18/30(36) kV

Nominal Cross Section Area

Capacitance

Inductance

Current Rating

mm²

μF/mm

mH/km

A

50

0.14

0.46

201

70

0.15

0.43

245

95

0.17

0.41

292

120

0.18

0.40

330

150

0.19

0.38

368

185

0.21

0.37

413

240

0.23

0.35

475


Dimension and Weight:

6/10(12) kV

Nominal
Cross Section Area

Nominal Conductor Diameter

Nominal Insulation Thickness

Nominal
Screen Cross Section Area

Nominal
Core Sheath Thickness

Nominal Core Diameter

Nominal Bedding Thickness

Nominal Steel Wire Diameter

Serving
Thickness

Overall
Diameter

Weight

mm²

mm

mm

mm²

mm

mm

mm

mm

mm

mm

kg/m

35

7.0

3.4

16

2.5

22

2

3.15

3.5

65

6.3

50

8.2

3.4

16

2.5

23

2

3.15

3.5

68

7.0

70

9.9

3.4

16

2.5

25

2

4.0

3.5

72

8.8

95

11.5

3.4

16

2.5

26

2

4.0

3.5

76

10.0

120

13.0

3.4

16

2.5

28

2

4.0

3.5

79

11.2

150

14.5

3.4

25

2.5

29

2

4.0

3.5

82

12.3

185

16.1

3.4

25

2.5

31

2

5.0

4.0

89

15.5

240

18.6

3.4

25

2.5

33

2

5.0

4.0

94

17.8

12/20(24) kV

Nominal
Cross Section Area

Nominal Conductor Diameter

Nominal Insulation Thickness

Nominal
Screen Cross Section Area

Nominal
Core Sheath Thickness

Nominal Core Diameter

Nominal Bedding Thickness

Nominal Steel Wire Diameter

Serving
Thickness

Overall
Diameter

Weight

mm²

mm

mm

mm²

mm

mm

mm

mm

mm

mm

kg/m

35

7.0

5.5

16

2.5

26

2

3.15

3.5

74

7.6

50

8.2

5.5

16

2.5

27

2

3.15

3.5

77

8.3

70

9.9

5.5

16

2.5

29

2

4.0

3.5

81

10.3

95

11.5

5.5

16

2.5

30

2

4.0

3.5

85

11.5

120

13.0

5.5

16

2.5

32

2

4.0

3.5

88

12.7

150

14.5

5.5

25

2.5

33

2

4.0

3.5

91

13.9

185

16.1

5.5

25

2.5

35

2

5.0

4.0

98

17.2

240

18.6

5.5

25

2.5

38

2

5.0

4.0

103

19.5

18/30(36) kV

Nominal
Cross Section Area

Nominal Conductor Diameter

Nominal Insulation Thickness

Nominal
Screen Cross Section Area

Nominal
Core Sheath Thickness

Nominal Core Diameter

Nominal Bedding Thickness

Nominal Steel Wire Diameter

Serving
Thickness

Overall
Diameter

Weight

mm²

mm

mm

mm²

mm

mm

mm

mm

mm

mm

kg/m

50

8.2

8.0

16

2.5

33

2

3.15

3.5

88

10.0

70

9.9

8.0

16

2.5

34

2

4.0

3.5

93

12.3

95

11.5

8.0

16

2.5

36

2

4.0

3.5

96

13.5

120

13.0

8.0

16

2.5

37

2

4.0

4.0

100

14.8

150

14.5

8.0

25

2.5

39

2

4.0

4.0

103

16.0

185

16.1

8.0

25

2.5

40

2

5.0

4.0

109

19.5

240

18.6

8.0

25

2.5

43

2

5.0

4.0

114

22.0