| Rolling Stock Cables | ||||||||||||||||||
|
||||||||||||||||||
RSE/STD/024 Part 6 Types XIII Rolling Stock Cables
300/500V Multicore Standard Wall Cables

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles
Construction
Conductor:Flexible Stranded Tinned Copper
Insulation:Cross linked EPR rubber type EI 107
Sheath:Cross linked EVA rubber type EM 104
Chemical & Environmental Properties
EN 60684-2 :No fluorine
EN 50305; EN 60811-2-1:Resistance to oil & fuel
EN 50305:Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 :Hazard levels HL1, HL2/HL3
DIN 5510-2:Protection level 1/2/3/4
BS 6853:Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101:FO
Fire Performance in general
| EN 50265-2-1; IEC 60332-1; BS 4066-1 | Vertical flame propogation for a single insulated wire/cable |
|---|---|
EN 50266-2-4 + EN 50305; IEC 60332-3C |
Fire propagation of bunched wires and cables |
VDE 0472 Teil 804; BS 4066-3; NFC 32070 |
|
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 |
Smoke density |
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 |
Halogen Free |
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 |
Corrosivity of gases (Acidity & Conductivity) |
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 |
Toxicity index |
NFF 16101; NFF 63808; BS6853 |
Smoke index |
No.of core |
Nominal Cross |
Nominal Diameter of |
Nominal Overall |
Nominal Weight |
Maximum Conductor |
|---|---|---|---|---|---|
mm2 |
No/mm |
mm |
kg/km |
Ω/km |
|
12 |
1.0 |
32/0.2 |
20.3 |
309 |
20.0 |
42 |
1.5 |
30/0.25 |
38.1 |
1775 |
13.7 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information