| Rolling Stock Cables | ||||||||||||||||||
|
||||||||||||||||||
Rolling Stock Cable
NF F 63-826 Standard Wall Power & Control Cable
FIREROL FRF-SW-1.5S/FRF-SW-3S
1500/3000 V -Standard Wall Single Core Sheathed Cables
Application
1500/3000 V -Standard Wall Single Core Sheathed Cables are used as power and control cable for protected
installations inside and outside of rail and transport vehicles, where handling and installation cost are an
important factor, suitable for use in control, auxiliary and main circuit wiring such as cable harnesses,
switchboards and control panels, driver desks etc
Construction
Conductor: Stranded tinned copper wires to IEC 60228 Class 5
Insulation: Halogen free compound
Sheath: Halogen free compound

A. Conductor B. Insulation C. Sheath
Electrical & Mechanical Properties
Nominal Voltage:1500V, 3000V
Maximum Conductor Temperature:90°C/105°C
Minimum Permissible Ambient Temperature:-25°C~90°C
Bending Radius:4 × Overall Diameter
Standards
NF F 63-826
NF F 16-101
BS 6853
Fire Performance in general
| EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) | Vertical flame propogation for a single insulated wire or cable |
|---|---|
| EN 50266-2-4 + EN 50305; IEC 60332-3-24; NF C 32-070 2.2 (C1); VDE 0472 Teil 804 |
Vertical flame spread of vertically mounted bunched wires or cables |
| EN 50268-2; IEC 61034-2; NF C 32-073 ; NF C 20-902; NF F 16 101; VDE 0472 Teil 816 |
Low Smoke Emission |
| EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 | Halogen Free |
| EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 | Low Corrosivity (Acidity & Conductivity) |
| EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 | Low Toxicity |
| NFF 16101; NFF 63808; BS6853 | Smoke index |
| EN45545-2 | Requirement for fire behavior of materials & components R15/R16 |
FRF-SW-1.5S 1500V
| Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter | Weight | |
|---|---|---|---|---|---|---|
| Min. | Max. | |||||
| mm² | No/mm | mm | mm | mm | mm | kg/km |
| 1.5 | 30/0.25 | 2.3 | 1.5 | 8.9 | 9.9 | 130 |
| 2.5 | 50/0.25 | 2.3 | 1.5 | 9.3 | 10.3 | 145 |
| 10.0 | 80/0.40 | 2.3 | 1.8 | 11.9 | 13.3 | 290 |
| 50.0 | 396/0.40 | 2.5 | 2.2 | 18.3 | 20.3 | 850 |
| 120.0 | 608/0.50 | 2.8 | 2.6 | 25.0 | 27.5 | 1770 |
| 150.0 | 756/0.50 | 2.8 | 2.6 | 26.7 | 29.3 | 2150 |
| 185.0 | 925/0.50 | 2.9 | 2.8 | 29.0 | 31.8 | 2530 |
FRF-SW-3S 3000V
| Nominal Cross Sectional Area | Number & Nominal Diameter of Strands | Nominal Insulation Thickness | Nominal Sheath Thickness | Overall Diameter | Weight | |
|---|---|---|---|---|---|---|
| Min. | Max. | |||||
| mm² | No/mm | mm | mm | mm | mm | kg/km |
| 150.0 | 756/0.50 | 3.6 | 2.6 | 28.2 | 30.9 | 2270 |
| 185.0 | 925/0.50 | 3.7 | 2.8 | 30.5 | 33.4 | 2660 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information