Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Rolling Stock Cables

 FIREROL FRF-HT-3S-EF

    

                                                          A. Conductor B. Insulation C. Reinforcement D. Sheath

Application

These cables are used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor, suitable for used in control, auxiliary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor

Stranded tinned copper wires to IEC 60228 Class 6

Insulation
Halogen free silicone rubber

Reinforcement
Textile braid

Sheath
Halogen free silicone rubber

Electrical & Mechanical Properties

Nominal Voltage 3000V
Maximum Conductor Temperature 120°C/140°C
Minimum Permissible Ambient Temperature -40°C~+135°C
Bending Radius 3 × Overall Diameter

Standards
NF F 63-827
NF F 16-101

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index

FRF-HT-3S-EF 3000V

Nominal Cross Sectional Area

Number & Nominal Diameter of Strands

Nominal Insulation Thickness

Overall Diameter

Weight

Min.

Max.

mm²

No/mm

mm

mm

mm

kg/km

25.0

800/0.20

2.8

12.0

13.2

390

35.0

1120/0.20

2.8

13.2

14.7

500

50.0

705/0.30

3.0

15.2

16.7

680

70.0

990/0.30

3.2

17.1

18.8

930

95.0

1340/0.30

3.2

19.0

21.0

1150

120.0

1690/0.30

3.3

21.0

23.1

1470

150.0

2123/0.30

3.3

22.8

25.0

1800

185.0

1470/0.40

3.4

24.7

27.1

2240

240.0

1905/0.40

3.6

27.6

31.2

2820