Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Belden Equivalent Cables

Coaxial Cables

Control Cables

Fiber Optic Cables

Flexible Cables

Instrumentation Cables

Lan Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables

Telephone Cables

Airport Cables

Bus Cables

Cable Glands

Data Cable

Heat Detection Cables
High Temperature Cables
Highway Cables
Marine, OIL,GAS & Petrochemical Cables
Special Cables
Spiral Cables
Thermocouple Cables
     
  indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Rolling Stock Cables

  FIREROL FRL-TW-05M-OS

FIREROL FRL-TW-05M-OS     

                                  A.Conductor     B.Insulation      C.Screen         D.Sheath

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Tinned annealed copper wires as defined in EN 50306-2

Insulation
LSZH special compound

Overal screen
Tinned annealed copper wires

Outer sheath
LSZH special compound (S1 & S2)

Electrical & Mechanical Properties

Nominal Voltage 300/500 V
Maximum Conductor Temperature +120/+150 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 10 x Overall Diameter

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070  
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-TW-05M-OS 300/500 V

NUMBER OF CORES AND NOMINAL CROSS SECTION

MINIMUM THICKNESS OF SHEATH AT ANY POINT

OVERALL DIAMETER

WEIGHT

(mm2)

(mm)

min. (mm)

max. (mm)

(kg/km)

2 x 0.5

0.20

3.5

4.3

30

3 x 0.5

0.20

3.7

4.5

30

4 x 0.5

0.20

4.0

5.0

40

2 x 0.75

0.20

3.9

4.7

30

3 x 0.75

0.20

4.0

5.0

40

4 x 0.75

0.20

4.5

5.5

60

2 x 1

0.20

4.2

5.2

40

3 x 1

0.20

4.5

5.5

55

4 x 1

0.20

5.0

6.0

70

2 x 1.5

0.20

5.1

6.1

60

3 x 1.5

0.20

5.4

6.4

80

4 x 1.5

0.20

6.0

7.0

100

2 x 2.5

0.20

6.4

7.4

90

3 x 2.5

0.20

6.8

7.8

120

4 x 2.5

0.20

7.5

8.5

140