Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Rolling Stock Cables

Rolling Stock Cable

EN 50264 Medium Wall Power & Control Cable

FIREROL FRL-MW-05M-OS-AS+, FRL-MW-1M-OS-AS+

    

                                   A.Conductor      B.Insulation       C.Screen            D.Sheath

Application

-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and installation cost are an important factor.

-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction

Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5

Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 110)

Overal screen
Tinned annealed copper wires

Outer sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104

Electrical & Mechanical Properties

Nominal Voltage 300/500 V or 0.6/1 kV
Maximum Conductor Temperature +90 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 10 x Overall Diameter (D<12mm);

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index
IEC60331-21 The circuit integrity test under fire of cables rated 0.6/1.0kV and below

FRL-MW-05M-OS-AS+ 300/500 V

Nominal
Cross-Sectional
Area
(a)

Conductor
Diameter
(b)

Min. Mean
Thickness
of Insulation

Core
Dimensions

Min.
Screen
Wire
Diameter

Min.
Average
Sheath
Thickness

Overall Diameter

Weight

Conductor Resistance

Insulation Resistance

EI 110

EI 106/7/8/9

Min.

Max.

Min.

Max.

20°C

20°C

20°C

n x mm2

mm

mm

mm

mm

mm

mm

mm

mm

kg/km

Ω/km

MΩ x km

MΩ x km

2 x 1

1.25

0.4

2.24

2.64

0.16

0.6

6.24

7.34

81

20.0

15.0

7.5

4 x 1

1.25

0.4

2.24

2.64

0.16

0.7

7.24

8.44

132

20.0

15.0

7.5

7 x 1

1.25

0.4

2.24

2.64

0.16

0.7

8.44

9.84

203

20.0

15.0

7.5

9 x 1

1.25

0.4

2.24

2.64

0.21

0.8

10.44

12.14

275

20.0

15.0

7.5

12 x 1

1.25

0.4

2.24

2.64

0.21

0.8

11.14

12.94

346

20.0

15.0

7.5

19 x 1

1.25

0.4

2.24

2.64

0.26

1.0

13.44

15.64

538

20.0

15.0

7.5

24 x 1

1.25

0.4

2.24

2.64

0.26

1.0

15.44

18.04

667

20.0

15.0

7.5

32 x 1

1.25

0.4

2.24

2.64

0.26

1.0

16.84

19.64

846

20.0

15.0

7.5

37 x 1

1.25

0.4

2.24

2.64

0.26

1.0

17.44

20.34

953

20.0

15.0

7.5

40 x 1

1.25

0.4

2.24

2.64

0.26

1.2

18.44

21.54

1044

20.0

15.0

7.5

 

4 x 1.5

1.5

0.5

2.64

3.14

0.16

0.7

8.24

9.64

180

13.7

14.0

7.0

7 x 1.5

1.5

0.5

2.64

3.14

0.21

0.7

9.84

11.54

295

13.7

14.0

7.0

9 x 1.5

1.5

0.5

2.64

3.14

0.21

1.0

12.34

14.44

395

13.7

14.0

7.0

12 x 1.5

1.5

0.5

2.64

3.14

0.21

1.0

13.24

15.44

497

13.7

14.0

7.0

19 x 1.5

1.5

0.5

2.64

3.14

0.26

1.0

15.54

18.14

750

13.7

14.0

7.0

24 x 1.5

1.5

0.5

2.64

3.14

0.26

1.2

18.34

21.44

955

13.7

14.0

7.0

32 x 1.5

1.5

0.5

2.64

3.14

0.26

1.2

20.04

23.44

1215

13.7

14.0

7.0

37 x 1.5

1.5

0.5

2.64

3.14

0.26

1.2

20.74

24.24

1372

13.7

14.0

7.0

 

4 x 2.5

1.95

0.5

3.14

3.64

0.21

0.7

9.44

11.04

249

8.21

13.0

6.5

7 x 2.5

1.95

0.5

3.14

3.64

0.21

0.8

11.34

13.24

398

8.21

13.0

6.5

9 x 2.5

1.95

0.5

3.14

3.64

0.26

1.0

14.14

16.54

539

8.21

13.0

6.5

12 x 2.5

1.95

0.5

3.14

3.64

0.26

1.0

15.24

17.74

681

8.21

13.0

6.5

19 x 2.5

1.95

0.5

3.14

3.64

0.26

1.2

18.04

21.04

1027

8.21

13.0

6.5

24 x 2.5

1.95

0.5

3.14

3.64

0.26

1.2

20.84

24.34

1278

8.21

13.0

6.5

(a)= One earth conductor (green/yellow) can be included upon request

(b)= For information,indicative only

FRL-MW-1M-OS-AS+ 0.6/1 kV

Nominal
Cross-Sectional
Area
(a)

Conductor
Diameter
(b)

Min. Mean
Thickness
of Insulation

Core
Dimensions

Min.
Screen
Wire
Diameter

Min.
Average
Sheath
Thickness

Overall Diameter

Weight

Conductor Resistance

Insulation Resistance

EI 110

EI 106/7/8/9

Min.

Max.

Min.

Max.

20°C

20°C

20°C

mm2

mm

mm

mm

mm

mm

mm

mm

mm

kg/km

Ω/km

MΩ x km

MΩ x km

TWO CORES

1.5

1.5

0.7

3.04

3.54

0.16

0.70

8.14

10.14

121

13.7

21.0

10.5

2.5

1.95

0.7

3.44

4.04

0.16

0.70

8.94

10.94

157

8.21

17.2

8.6

4

2.5

0.7

4.04

4.64

0.21

0.80

10.44

12.94

224

5.09

14.2

7.1

6

3.0

0.7

4.44

5.24

0.21

0.80

11.14

13.84

287

3.39

12.2

6.1

10

3.9

0.7

5.34

6.14

0.21

1.00

13.64

16.84

424

1.95

9.8

4.9

16

5.0

0.7

6.34

7.44

0.26

1.00

16.24

20.04

606

1.24

7.9

3.9

25

6.4

0.9

8.04

9.34

0.26

1.20

20.04

24.84

909

0.795

7.3

3.6

35

7.7

0.9

9.24

10.84

0.31

1.40

23.04

28.14

1213

0.565

6.7

3.3

50

9.2

1.0

10.84

12.64

0.31

1.40

26.64

32.54

1631

0.393

6.3

3.1

THREE CORES

1.5

1.5

0.7

3.04

3.54

0.16

0.70

8.64

10.64

156

13.7

21.0

10.5

2.5

1.95

0.7

3.44

4.04

0.16

0.70

9.44

11.64

207

8.21

17.2

8.6

4

2.5

0.7

4.04

4.64

0.21

0.80

11.04

13.54

295

5.09

14.2

7.1

6

3.0

0.7

4.44

5.24

0.21

0.80

11.84

14.54

384

3.39

12.2

6.1

10

3.9

0.7

5.34

6.14

0.26

1.00

14.64

18.24

593

1.95

9.8

4.9

16

5.0

0.7

6.34

7.44

0.26

1.20

17.64

21.54

848

1.24

7.9

3.9

25

6.4

0.9

8.04

9.34

0.26

1.20

21.54

26.34

1251

0.795

7.3

3.6

35

7.7

0.9

9.24

10.84

0.31

1.40

24.74

30.04

1674

0.565

6.7

3.3

50

9.2

1.0

10.84

12.64

0.31

1.60

28.54

34.84

2309

0.393

6.3

3.1

FOUR CORES

1.5

1.5

0.7

3.04

3.54

0.16

0.70

9.34

11.54

194

13.7

21.0

10.5

2.5

1.95

0.7

3.44

4.04

0.21

0.80

10.64

13.14

280

8.21

17.2

8.6

4

2.5

0.7

4.04

4.64

0.21

0.80

12.04

14.74

371

5.09

14.2

7.1

6

3.0

0.7

4.44

5.24

0.21

1.00

13.34

16.34

503

3.39

12.2

6.1

10

3.9

0.7

5.34

6.14

0.26

1.00

16.14

19.74

752

1.95

9.8

4.9

16

5.0

0.7

6.34

7.44

0.26

1.20

19.54

23.84

1082

1.24

7.9

3.9

25

6.4

0.9

8.04

9.34

0.31

1.40

24.24

29.54

1666

0.795

7.3

3.6

3x35+25

7.7/6.4

0.9/0.9

9.24/8.04

10.84/9.34

0.31

1.40

27.14

33.14

2152

0.565/0.795

6.7

3.3

3x50+25

9.2/6.4

1.0/0.9

10.84/8.04

12.64/9.34

0.31

1.60

31.74

38.44

2946

0.393/0.795

6.3

3.1

(a)= For information,indicative only