Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Rolling Stock Cables

  FIREROL FRL-HT-3S/FRL-HT-6SU

FIREROL FRL-HT-3S/FRL-HT-6SU    

                                                                A.Conductor           B.Insulation    C.Sheath  

Construction

Conductor
flexible tinned annealed copper wires(red copper only for 150° C core temperature)class 5 according to HD 383

Insulation
silicon rubber according to EN 50382-1 (EI 112)

Outer sheath
LSZH elastomeric compound according to EN 50382-1 (EM 105. EM 106 or EM 107)

Electrical & Mechanical Properties

Nominal Voltage 1.8/3 kV or 3.6/6 kV
Maximum Conductor Temperature +90 deg (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 deg (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
  4 x Overall Diameter (D>12mm)

Chemical & Environmental Properties

EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 Resistance to ozone

Fire Performance for rolling stock application

EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general

EN 50265-2-1; IEC 60332-1-2; NF C 32-070 2.1 (C2) Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3-24;
NF C 32-070 2.2 (C1); VDE 0472 Teil 804
Vertical flame spread of vertically mounted bunched wires or cables
EN 50268-2; IEC 61034-2; NF C 32-073 ;
NF C 20-902; NF F 16 101; VDE 0472 Teil 816
Low Smoke Emission
EN 50267-2-1; IEC 60754-1; NF C 32-074;NF C 20-454; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; NF C 32-074;NF C 20-453; VDE 0472 Teil 813 Low Corrosivity (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Low Toxicity
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-HT-3S 1.8/3KV

NOMINAL CROSS-SECTIONAL AREA

CONDUCTOR DIAMETER (a)

MIN. MEAN THICKNESS OF INSULATION

MIN. AVERAGE SHEATH THICKNESS

OVERALL DIAMETER

WEIGHT

RESISTANCE OF CONDUCTOR AT 20°C

MIN. INSULATION RESISTANCE

min

max

TINNED CONDUCTOR

PLAIN CONDUCTOR

AT

+20℃MIN.

AT +150℃MIN.

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

Ω/km

MΩ·km

MΩ·km

1.5

1.5

1.3

1.4

6.8

7.9

70

13.7

13.3

670

1.30

2.5

1.95

1.3

1.4

7.2

8.4

80

8.21

7.98

570

1.10

4

2.5

1.3

1.4

7.7

9.0

100

5.09

4.95

480

0.90

6

3.0

1.3

1.4

8.2

9.6

120

3.39

3.30

420

0.80

10

3.9

1.5

1.4

9.4

11.0

190

1.95

1.91

380

0.70

16

5.0

1.5

1.4

10.5

12.2

240

1.24

1.21

310

0.60

25

6.4

1.8

1.4

12.3

14.4

340

0.795

0.780

300

0.60

35

7.7

1.8

1.4

13.6

15.9

440

0.565

0.554

250

0.50

50

9.2

1.8

1.4

15.0

17.5

580

0.393

0.386

220

0.40

70

11.0

1.8

1.5

16.8

19.7

780

0.277

0.272

200

0.40

95

12.5

2.2

1.5

19.0

22.2

1020

0.210

0.206

190

0.40

120

14.2

2.2

1.6

20.8

24.3

1270

0.164

0.161

180

0.30

150

15.8

2.2

1.6

22.3

26.1

1560

0.132

0.129

160

0.30

185

17.5

2.4

1.7

24.5

28.6

1890

0.108

0.106

160

0.30

240

20.1

2.4

1.8

27.1

31.7

2480

0.0817

0.0801

140

0.20

300

22.5

2.4

1.9

29.5

34.6

2990

0.0654

0.0641

120

0.20

400

25.8

2.6

2.0

33.2

38.9

4010

0.0495

0.0486

120

0.20

FRL-HT-6S 3.6/6kV

NOMINAL CROSS-SECTIONAL AREA

CONDUCTOR DIAMETER (a)

MIN. MEAN THICKNESS OF INSULATION

MIN. AVERAGE SHEATH THICKNESS

OVERALL DIAMETER

WEIGHT

RESISTANCE OF CONDUCTOR AT 20°C

MIN. INSULATION RESISTANCE

min

max

TINNED CONDUCTOR

PLAIN CONDUCTOR

AT

+20℃MIN.

AT +150℃MIN.

mm2

mm

mm

mm

mm

mm

kg/km

Ω/km

Ω/km

MΩ·km

MΩ·km

2.5

1.95

2.6

1.4

9.9

11.6

130

8.21

7.98

870

1.70

4

2.5

2.6

1.4

10.4

12.2

150

5.09

4.95

750

1.50

6

3.0

2.6

1.4

10.9

12.8

180

3.39

3.30

670

1.30

10

3.9

2.6

1.4

11.8

13.8

240

1.95

1.91

570

1.10

16

5.0

2.6

1.4

12.8

15.0

300

1.24

1.21

480

0.90

25

6.4

2.9

1.4

14.7

17.2

410

0.795

0.780

430

0.80

35

7.7

2.9

1.4

15.9

18.6

510

0.565

0.554

380

0.70

50

9.2

2.9

1.5

17.5

20.5

660

0.393

0.386

330

0.60

70

11.0

2.9

1.5

19.2

22.4

870

0.277

0.272

280

0.50

95

12.5

2.9

1.6

20.8

24.3

1100

0.210

0.206

250

0.50

120

14.2

2.9

1.6

22.4

26.2

1330

0.164

0.161

230

0.40

150

15.8

2.9

1.7

24.1

28.2

1640

0.132

0.129

210

0.40

185

17.5

3.2

1.8

26.4

30.9

1990

0.108

0.106

210

0.40

240

20.1

3.4

1.9

29.4

34.4

2620

0.0817

0.0801

190

0.30

300

22.5

3.4

1.9

31.7

37.1

3120

0.0654

0.0641

170

0.30

400

25.8

3.4

2.0

35.0

40.9

4150

0.0495

0.0486

150

0.30