| Rolling Stock Cables | ||||||||||||||||||
  | 
            ||||||||||||||||||
 Rolling Stock Cables      
      RS 485 Databus Cables 300/500 V
FRL-MVB-02Y(ST)CH-IOS-xPyS/FRL-MVB-02YCH-OS-xPyS
Application
120 Ohm data transmission cables
Construction
Multipair Databus RS 485 Double Screened Cable
Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
Insulation: Cross linked foam PE or foam skin PE
Cable Element: Twisted pair
Pair Screen:Individual Aluminium tape
Overall Screen: Copper wire braid
Outer Sheath: Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1
Multipair Databus RS 485 Single Screened Cable
Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2)
Insulation: Cross linked foam PE or foam skin PE
Cable Element: Twisted pair
Overall Screen: Copper wire braid
Outer Sheath: Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1
Electrical Characteristic
Impedance:120 ohm ±15%
Capacitance:41nF/Km@1KHz
Insulation Resistance:5000 M ohm
Chemical & Environmental Properties
EN 60684-2: No fluorine
EN 50305; EN 60811-2-1: Resistance to mineral oil & fuel oil, acid & alkali
EN 50305 :Resistance to ozone
Fire Performance for Rolling Stock Application
EN 50306-2: Hazard levels HL1, HL2/HL3
DIN 5510-2: Protection level 1/2/3/4
BS 6853: Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101: F0
EN45545-2: R15 Interior/ R16 Exterior HL1, HL2, HL3
FRL-MVB-02Y(ST)CH-IOS-xPyS 300/500 V
| No.of Pairs | Cross Sectional Area mm2 | Number and Nominal Diameter of Strands mm  | 
                            Voltage Rating V  | 
                            Nominal Overall mm  | 
                            Nominal Weight kg/km | 
|---|---|---|---|---|---|
| 1 | 0.22 | 7/0.2 | 300/500 | 4.5 | 58 | 
| 2 | 0.22 | 7/0.2 | 300/500 | 6.2 | 79 | 
| 4 | 0.22 | 7/0.2 | 300/500 | 6.5 | 118 | 
| 1 | 0.5 | 16/0.2 | 300/500 | 6.6 | 79 | 
| 2 | 0.5 | 16/0.2 | 300/500 | 9.0 | 105 | 
| 4 | 0.5 | 16/0.2 | 300/500 | 9.8 | 145 | 
| 1 | 0.75 | 24/0.2 | 300/500 | 9.5 | 115 | 
| 2 | 0.75 | 24/0.2 | 300/500 | 10.3 | 135 | 
| 4 | 0.75 | 24/0.2 | 300/500 | 11.6 | 182 | 
| 1 | 1 | 30/0.2 | 300/500 | 11.5 | 125 | 
| 2 | 1 | 30/0.2 | 300/500 | 12.5 | 150 | 
| 4 | 1 | 30/0.2 | 300/500 | 13.5 | 180 | 
300/500V Multipair Databus RS 485 Single screened Cable
Cross- sectional Area :0.22mm2-1mm2
Voltage rating :300/500V
Conductor:Flexible Stranded Tinned Copper
Number of pair:1-4
Conductor class :IEC 60228 Class 5
Insulation:Cross linked Foam PE
Screen:Copper Wire Braid
Jacket:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1
Fire Standard:BS 6853 Category la,lb and 11 and NF F 16-101 FO
Electrical Characteristic
Impedance:120 ohm ±15%
Capacitance:41nF/Km@1KHz
Insulation Resistance:5000 M ohm
| No. of Pairs | Cross Sectional Area mm2 | Number and Nominal Diameter of Strands mm  | 
                            Voltage Rating V | Nominal Overall mm  | 
                            Nominal Weight kg/km | 
|---|---|---|---|---|---|
| 1 | 0.22 | 7/0.2 | 300/500 | 4.2 | 55 | 
| 2 | 0.22 | 7/0.2 | 300/500 | 5.9 | 75 | 
| 4 | 0.22 | 7/0.2 | 300/500 | 6.2 | 115 | 
| 1 | 0.5 | 16/0.2 | 300/500 | 6.3 | 75 | 
| 2 | 0.5 | 16/0.2 | 300/500 | 8.5 | 100 | 
| 4 | 0.5 | 16/0.2 | 300/500 | 9.4 | 140 | 
| 1 | 0.75 | 24/0.2 | 300/500 | 9.0 | 110 | 
| 2 | 0.75 | 24/0.2 | 300/500 | 9.7 | 130 | 
| 4 | 0.75 | 24/0.2 | 300/500 | 11.1 | 178 | 
| 1 | 1 | 30/0.2 | 300/500 | 11.0 | 120 | 
| 2 | 1 | 30/0.2 | 300/500 | 12.0 | 145 | 
| 4 | 1 | 30/0.2 | 300/500 | 13.0 | 175 | 
300/500V Multipair Databus RS 485 Single screened Cable
Cross- sectional Area :0.22mm2-1mm2
Voltage rating :300/500V
Conductor:Flexible Stranded Tinned Copper
Number of pair:1-4
Conductor class :IEC 60228 Class 5
Insulation:Cross linked Foam PE
Screen:Copper Wire Braid
Jacket:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1
Fire Standard:BS 6853 Category la,lb and 11 and NF F 16-101 FO
Electrical Characteristic
Impedance:120 ohm ±15%
Capacitance:41nF/Km@1KHz
Insulation Resistance:5000 M ohm
| No. of Pairs | Cross Sectional Area mm2 | Number and Nominal Diameter of Strands mm  | 
                            Voltage Rating V | Nominal Overall mm  | 
                            Nominal Weight kg/km | 
|---|---|---|---|---|---|
| 1 | 0.22 | 7/0.2 | 300/500 | 4.2 | 55 | 
| 2 | 0.22 | 7/0.2 | 300/500 | 5.9 | 75 | 
| 4 | 0.22 | 7/0.2 | 300/500 | 6.2 | 115 | 
| 1 | 0.5 | 16/0.2 | 300/500 | 6.3 | 75 | 
| 2 | 0.5 | 16/0.2 | 300/500 | 8.5 | 100 | 
| 4 | 0.5 | 16/0.2 | 300/500 | 9.4 | 140 | 
| 1 | 0.75 | 24/0.2 | 300/500 | 9.0 | 110 | 
| 2 | 0.75 | 24/0.2 | 300/500 | 9.7 | 130 | 
| 4 | 0.75 | 24/0.2 | 300/500 | 11.1 | 178 | 
| 1 | 1 | 30/0.2 | 300/500 | 11.0 | 120 | 
| 2 | 1 | 30/0.2 | 300/500 | 12.0 | 145 | 
| 4 | 1 | 30/0.2 | 300/500 | 13.0 | 175 | 