Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

EAPSP n×1×1.4

EAPSP n×1×1.4

Application

The cables are used as railway cables and can be installed directly into the ground or in ducts.

Standards

RENFE E.T. 03.365.051.6

Construction

Conductors: Soft annealed solid copper, 1.4 mm nominal diameter.

Insulation: PE insulation.

Stranding: Cores are helically stranded in concentric layers.

Core Wrapping

Plastic tape(s) with overlapping.

Moisture Barrier

One laminated sheath made of aluminium tape (0.2mm thick) coated with copolymer on at least one side is

applied longitudinally with overlap.

Inner Sheath

PE sheath.

Armour

One corrugated steel tape is longitudinally applied with overlap.

Outer Sheath

PE sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter mm 1.4
Maximum Conductor Resistance Ω/km 11.7
Minimum Insulation Resistance @500 V DC MΩ.km 25000
Resistance Unbalance % 2
Test Voltage @50Hz 1min
Core to Core Veff 2100
Core to Screen Veff 2500
Core to Armouring Veff 2000

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD

Temperature Range: -30℃ to +70℃ (during operation);

                                 -10℃ +50℃ (during installation)

Dimensions And Weight

Cable Code Number of
Cores
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal
Weight
kg/km
Inner Outer
1.4mm Conductor, 2.6mm Insulated Wire
RS/EAPSP-2Y(L)2Y(SR)2Y-4C1.4 4 1.3 1.4 15.7 270
RS/EAPSP-2Y(L)2Y(SR)2Y-7C1.4 7 1.3 1.4 17.1 350
RS/EAPSP-2Y(L)2Y(SR)2Y-9C1.4 9 1.3 1.4 19.9 420
RS/EAPSP-2Y(L)2Y(SR)2Y-12C1.4 12 1.3 1.4 20.0 480
RS/EAPSP-2Y(L)2Y(SR)2Y-19C1.4 19 1.3 1.4 22.0 630
RS/EAPSP-2Y(L)2Y(SR)2Y-27C1.4 27 1.3 1.4 24.8 810
RS/EAPSP-2Y(L)2Y(SR)2Y-37C1.4 37 1.3 1.4 26.9 1010
RS/EAPSP-2Y(L)2Y(SR)2Y-48C1.4 48 1.3 1.4 29.7 1240
RS/EAPSP-2Y(L)2Y(SR)2Y-61C1.4 61 1.3 1.4 31.8 1490