Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

CCPSSP-R-FR0.1

CCPSSP-R-FR0.1

Application

The cables are used as railway cables and can be installed directly into the ground or in ducts.

Standards

RENFE E.T. 03.365.051.6

Construction

Conductors: Soft annealed solid copper, 0.9 mm nominal diameter.

Insulation: PE insulation.

Cabling Element: Four insulated conductors are twisted together to form a quad.

Stranding: Quads are helically stranded in concentric layers.

Core Wrapping: At least one layer of water swellable material with overlapping.

Inner Sheath: PE sheath.

Screen: 1.4/1.8mm copper wires wrapping with one plastic tape (protection against interference).

Intermediate Sheath: PE sheath.

Armour: Two layers of steel tape (0.8mm thick).

Outer Sheath: PE sheath.

Electrical Characteristics at 20℃

Nominal Conductor Diameter mm 0.9
Maximum Conductor Resistance Ω/km 28.5
Minimum Insulation Resistance @500 V DC MΩ.km 25000
Mutual Capacitance @800Hz nF/km 41
Capacitance Unbalance @800Hz
K1 maximum individual value pF/460m 250
K9-12 maximum individual value pF/460m 250
ea1/2 maximum individual value pF/460m 1200
Attenuation
@1KHz dB/km 0.7
@10KHz dB/km 1.6
@30KHz dB/km 2.1
Test Voltage @50Hz 1min
Core to Core Veff 2100
Core to Screen Veff 2500
Core to Armouring Veff 2000
Reduction Factor @100V/km 50Hz 0.1

Mechanical and Thermal Properties

Minimum Bending Radius: 10×OD

Temperature Range: -30℃ to +70℃ (during operation);

                                 -5℃ to +50℃ (during installation)

Dimensions And Weight

Cable Code Number of
Quads
Nominal Sheath Thickness
mm
Maximum Overall
Diameter
mm
Nominal Weight
kg/km
Inner Inter. Outer
0.9mm Conductor, 1.8mm Insulated Wire
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-1Q0.9 1 1.5 1.5 1.6 23.7 1300
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-3Q0.9 3 1.5 1.5 1.6 27.7 1648
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-5Q0.9 5 1.5 1.5 1.6 31.5 1984
RS/CCPSSP-R-FR0.1-2Y(F)2YD2YB2Y-25Q0.9 25 1.7 1.7 1.8 51.3 4166