| Railway Cables | ||||||
|
||||||
FRA 213D SW4
Applications :
- FRA 213D SW4 cables are designed for flexible installations, inside and outside railway rolling stock.
Standards :
-
DIN 5510-2
Construction :


-
Inner conductor:Stranded silver plated copper.
Insulation:Crosslink PE(PEX).
Outer conductor(shield1):Silver plated copper.
-
Outer conductor(shield2):Silver plated copper.
-
Sheath:LSZH Elastomer.
Electrical Characteristics at 20 °C :
| Impedance | Ω | 50+/-2 |
|---|---|---|
| Nomina lCapacitance | pF/m | 101 |
| Minimum Insulation Resistance | MΩ.km | 100000 |
| Inner Conductor Resistance | MΩ/km | 5.8 |
| Outer Conductor Resistance | MΩ/km | 4.43 |
| Attenuation | ||
| @10MHz | dB/100m | 2 |
| @50MHz | dB/100m | 5 |
| @100MHz | dB/100m | 8 |
| @150MHz | dB/100m | 10 |
| @200MHz | dB/100m | 12 |
| @300MHz | dB/100m | 15 |
| @400MHz | dB/100m | 17 |
| @450MHz | dB/100m | 19 |
| @500MHz | dB/100m | 20 |
| @600MHz | dB/100m | 22 |
| @800MHz | dB/100m | 27 |
| @850MHz | dB/100m | 28 |
| @900MHz | dB/100m | 29 |
| @950MHz | dB/100m | 30 |
| @1000MHz | dB/100m | 31 |
| @1800MHz | dB/100m | 45 |
| @1900MHz | dB/100m | 47 |
| @2000MHz | dB/100m | 49 |
|---|---|---|
| @2400MHz | dB/100m | 55 |
| @3000MHz | dB/100m | 64 |
| @4000MHz | dB/100m | 79 |
| @5000MHz | dB/100m | 93 |
| @6000MHz | dB/100m | 106 |
| Velocity of propagation | % | 66 |
Mechanical and Thermal Properties :
-
Minimum Bending Radius:50mm (static)
-
Temperature Range:-40℃~+105℃
Dimensions and Weight :
| Conductor Construction No/mm | NominalInner Conductor Diameter mm | NominalOuter Conductor Diameter mm | NominalOverall Diameter mm | NominalWeight |
|---|---|---|---|---|
| 7/0.75 | 2.25 | 8.7 | 10.8 | 202 |