Application
Single Core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
● BS 6387
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Flame Barrier
Mica tape.
Insulation
Electron beam crosslinkable thin wall LSZH compound.
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section |
mm² |
0.5 |
0.75 |
1.0 |
1.5 |
2.5 |
| Maximum DC Conductor Resistance |
Ω/km |
40.1 |
26.7 |
20.0 |
13.7 |
8.21 |
| Voltage Rating |
KV |
0.45/0.75 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code |
No. of cores& Nominal
Conductor Cross Sectional
Area
No.×mm² |
Nominal
Diameter of
Strands
No/mm |
Nominal
Insulation
Thickness
mm |
Nominal
Overall
Diameter
mm |
Nominal
Weight
kg/km |
| FRA-TW-0.5SU-FR-1C0.5S |
1×0.5 |
16/0.20 |
0.30 |
2.0 |
8 |
| FRA-TW-0.5SU-FR-1C0.75S |
1×0.75 |
24/0.20 |
0.30 |
2.25 |
11 |
| FRA-TW-0.5SU-FR-1C1S |
1×1.0 |
32/0.2 |
0.35 |
2.50 |
14 |
| FRA-TW-0.5SU-FR-1C1.5S |
1×1.5* |
30/0.25 |
0.35 |
2.8 |
19 |
| FRA-TW-0.5SU-FR-1C2.5S |
1×2.5* |
50/0.25 |
0.35 |
3.2 |
29 |
*earth cable(coloured yellow/green)can be offered as an option.