Application
Single Core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
● BS 6387
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Flame Barrier
Mica tape.
Insulation
Electron beam crosslinkable medium wall LSZH compound.
Sheath
Electron beam crosslinkable LSZH compound.
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section |
mm² |
1.0 |
1.5 |
2.5 |
4.0 |
6.0 |
10 |
16 |
| Maximum Conductor Resistance |
Ω/km |
20.0 |
13.7 |
8.21 |
5.09 |
3.39 |
1.95 |
1.24 |
| Voltage Rating |
KV |
1.8/3 |
| Nominal Conductor Cross Section |
mm² |
25 |
35 |
50 |
70 |
95 |
150 |
| Maximum Conductor Resistance |
Ω/km |
0.795 |
0.565 |
0.393 |
0.277 |
0.21 |
0.132 |
| Voltage Rating |
KV |
1.8/3 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code |
No. of cores& Nominal
Conductor Cross
Sectional Area
No. x AWG |
Nominal Diameter
of Strands
No/mm |
Nominal Insulation
Thickness
mm |
Nominal Overall
Diameter
mm |
|
FRA-MW-3S-FR-1G1.5 |
1×1.5 |
30/0.25 |
0.8 |
3.7 |
26 |
FRA-MW-3S-FR-1G2.5 |
1×2.5 |
50/0.25 |
0.75 |
3.95 |
35 |
FRA-MW-3S-FR-1G4 |
1×4 |
56/0.3 |
0.95 |
4.95 |
55 |
FRA-MW-3S-FR-1G6 |
1×6 |
84/0.3 |
0.90 |
5.35 |
75 |
FRA-MW-3S-FR-1G10 |
1×10 |
80/0.4 |
1.05 |
6.80 |
130 |
FRA-MW-3S-FR-1G16 |
1×16 |
126/0.4 |
1.20 |
8.60 |
190 |
FRA-MW-3S-FR-1G25 |
1×25 |
196/0.4 |
1.35 |
10.2 |
280 |
FRA-MW-3S-FR-1G35 |
1×35 |
276/0.4 |
1.55 |
11.7 |
390 |
FRA-MW-3S-FR-1G50 |
1×50 |
396/0.4 |
1.85 |
13.8 |
550 |
FRA-MW-3S-FR-1G70 |
1×70 |
360/0.5 |
1.70 |
15.8 |
720 |
FRA-MW-3S-FR-1G95 |
1×95 |
475/0.5 |
1.90 |
17.6 |
960 |
FRA-MW-3S-FR-1G120 |
1×120 |
|
1.95 |
20.2 |
1180 |