Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Cables for Oil Industry

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)
Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Shipboard Cables(JIS)
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Railway Cables

0.6/1KV Single Core Medium Wall Traction Cables

Application

Single Core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.

Standards

● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0

Construction

Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.

Insulation
Electron beam crosslinkable medium wall LSZH compound.

Optional

FRA-MW-1S (Sheathed); FRA-MW-1S-OS (Screened & Sheathed)
FRA-MW-1SU-FR (Fire resistant & Unsheathed)

Electrical Characteristics at 20℃

Nominal Conductor Cross Section
mm²
0.5
0.75
1.0
1.5
2.5
4.0
6.0
Maximum Conductor Resistance
Ω/km
40.1
26.7
20.0
13.7
8.21
5.09
3.39
Voltage Rating
KV
0.6/1.0

 

Nominal Conductor Cross Section
mm²
10
16
25
35
50
70
95
Maximum Conductor Resistance
Ω/km
1.95
1.24
0.795
0.565
0.393
0.277
0.21
Voltage Rating
KV
0.6/1.0

 

Nominal Conductor Cross Section
mm²
120
150
185
240
300
400
Maximum Conductor Resistance
Ω/km
0.164
0.132
0.108
0.0817
0.654
0.0495
Voltage Rating
KV
0.6/1.0

Mechanical and Thermal Properties

Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃

Dimensions And Weight

Cable Code
No. of cores& Nominal
Conductor Cross
Sectional Area
No. x AWG
Nominal Diameter
of Strands
No/mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm

Nominal Weight
kg/km

FRA-MW-1SU-1G0.5

1×0.5

16/0.2

0.6

2.0

6

FRA-MW-1SU-1G0.75

1×0.75

24/0.2

0.6

2.2

8

FRA-MW-1SU-1G1

1×1.0

32/0.2

0.6

2.6

10

FRA-MW-1SU-1G1.5

1×1.5

30/0.25

0.7

3.1

20

FRA-MW-1SU-1G2.5

1×2.5

50/0.25

0.7

3.5

30

FRA-MW-1SU-1G4

1×4.0

56/0.3

0.7

4.1

50

FRA-MW-1SU-1G6

1×6.0

84/0.3

0.7

4.6

60

FRA-MW-1SU-1G10

1×10

80/0.4

0.7

5.5

110

FRA-MW-1SU-1G16

1×16

126/0.4

0.7

6.7

160

FRA-MW-1SU-1G25

1×25

196/0.40

0.9

8.5

240

FRA-MW-1SU-1G35

1×35

276/0.40

0.9

9.8

330

FRA-MW-1SU-1G50

1×50

396/0.40

1.0

11.5

460

FRA-MW-1SU-1G70

1×70

360/0.50

1.0

13.6

660

FRA-MW-1SU-1G95

1×95

475/0.50

1.1

15.1

860

FRA-MW-1SU-1G120

1×120

608/0.50

1.1

17.1

1080

FRA-MW-1SU-1G150

1×150

756/0.50

1.4

19.1

1370

FRA-MW-1SU-1G185

1×185

925/0.50

1.6

21.3

1690

FRA-MW-1SU-1G240

1×240

1221/0.50

1.7

24.1

2230

FRA-MW-1SU-1G300

1×300

1525/0.50

1.8

26.7

2780

FRA-MW-1SU-1G400

1×400

2013/0.50

2.0

30.5

3740