Application
Single core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation
Elect ron beam crosslinkable thin wall LSZH compound.
Screen(optional)
Copper Wire Screen (for screened & sheathed cables).
Outer Sheath(optional)
Electron beam crosslinkable LSZH compound (for screened & sheathed cables).
Optional
FRA-TW-0.75S (Sheathed)
FRA-TW-0.75SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section |
AWG |
20 |
18 |
16 |
14 |
12 |
10 |
| Maximum Conductor Resistance |
Ω/km |
28.3 |
17.9 |
14.1 |
8.3 |
6.8 |
3.6 |
| Voltage Rating |
KV |
0.45/0.75 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
FRA-TW-0.75SU (Unsheathed)
Cable Code |
No. of cores& Nominal
Conductor Cross Sectional Area
No. x AWG |
Nominal Diameter
of Strands
No/mm |
Nominal
Insulation
Thickness
mm |
Nominal
Overall
Diameter
mm |
Nominal
Weight
kg/km |
FRA-TW-0.75SU-1C20A |
1 x 20 |
19/0.2 |
0.18 |
1.5 |
7 |
FRA-TW-0.75SU-1C18A |
1 x 18 |
19/0.25 |
0.18 |
1.75 |
10 |
FRA-TW-0.75SU-1C16A |
1 x 16 |
19/0.3 |
0.18 |
2.0 |
14 |
FRA-TW-0.75SU-1C14A |
1 x 14 |
37/0.25 |
0.22 |
2.35 |
19 |
FRA-TW-0.75SU-1C12A |
1 x 12 |
37/0.3 |
0.28 |
2.77 |
28 |
FRA-TW-0.75SU-1C10A |
1 x 10 |
37/0.4 |
0.34 |
3.45 |
47 |
FRA-TW-0.75S-OS (Screened & Sheathed)
Cable Code |
No. of cores& Nominal
Conductor Cross Sectional Area
No. x AWG |
Nominal Diameter
of Strands
No/mm |
Nominal
Insulation
Thickness
mm |
Nominal
Overall
Diameter
mm |
Nominal
Weight
kg/km |
FRA-TW-0.75S-OS-1C20A |
1 x 20 |
19/0.2 |
0.18 |
2.5 |
17 |
FRA-TW-0.75S-OS-1C18A |
1 x 18 |
19/0.25 |
0.18 |
2.7 |
19.4 |
FRA-TW-0.75S-OS-1C16A |
1 x 16 |
19/0.3 |
0.18 |
2.9 |
24.2 |