Railway Cables
Railway Signalling & Control Cables Railway Telecom Cables Railway Power & Control Cables FIRERAIL Traction Cables

 

0.45/0.75KV Single Core Standard Wall Traction Cables

Application

0.45/0.75KV Single Core Standard Wall Traction Cables designed for protected, fixed installation inside and

outside railway vehicles for connecting fi xed and moving parts.

Reference Standards

BS 6853 -1a

DIN 5510-1 1-4

NFF 16-101 F0

Construction

0.45/0.75KV Single Core Standard Wall Traction Cables

Conductors

Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.

Insulation

Electron beam crosslinkable standard wall LSZH compound

Optional

FRA-SW-0.75S (Sheathed); FRA-SW-0.75S-OS (Screened & sheathed)

FRA-SW-0.75SU-FR (Fire resistant & Unsheathed)

Electrical Characteristics at 20℃

Nominal Conductor Cross Section mm² 1.0 1.5 2.5 4.0 6.0 10 16
Maximum Conductor Resistance Ω/km 20 13.7 8.21 5.09 3.39 1.95 1.24
Voltage Rating KV 0.45/0.75

Mechanical and Thermal Properties

Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)

Temperature Range:-40℃ to +120℃

Dimensions And Weight

Cable Code No. of cores& Nominal Conductor Cross Sectional
Area
No.×mm²
Nominal Diameter
of Strands
mm
Nominal Insulation
Thickness
mm
Nominal Overall
Diameter
mm
Nominal Weight
kg/km
FRA-SW-0.75SU-1G1 1×1.0 32/0.2 0.8 3.9 28
FRA-SW-0.75SU-1G1.5 1×1.5 30/0.25 0.8 4.2 34
FRA-SW-0.75SU-1G2.5 1×2.5 50/0.25 0.8 4.6 41
FRA-SW-0.75SU-1G4 1×4.0 56/0.3 0.8 5.2 64
FRA-SW-0.75SU-1G6 1×6.0 84/0.3 0.9 6.4 93
FRA-SW-0.75SU-1G10 1×10.0 80/0.4 0.9 7.5 141
FRA-SW-0.75SU-1G16 1×16.0 126/0.4 1.1 8.6 203

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information