Application
Single core power and control cable designed for protected, fi xed installation inside and outside railway vehicles for connecting fi xed and moving parts.
Standards
● BS 6853 -1a
● DIN 5510-1 1-4
● NFF 16-101 F0
Construction
Conductors
Circular Class 5 stranded plain or tinned copper to BS EN 60228: 2005 / BS 6360.
Insulation
Electron beam crosslinkable standard wall LSZH compound
Optional
FRA-SW-0.75S (Sheathed); FRA-SW-0.75S-OS (Screened & sheathed)
FRA-SW-0.75SU-FR (Fire resistant & Unsheathed)
Electrical Characteristics at 20℃
| Nominal Conductor Cross Section |
mm² |
1.0 |
1.5 |
2.5 |
4.0 |
6.0 |
10 |
16 |
| Maximum Conductor Resistance |
Ω/km |
20 |
13.7 |
8.21 |
5.09 |
3.39 |
1.95 |
1.24 |
| Voltage Rating |
KV |
0.45/0.75 |
Mechanical and Thermal Properties
Minimum Bending Radius:3×OD (OD<12mm); 4×OD (OD>12mm)
Temperature Range:-40℃ to +120℃
Dimensions And Weight
Cable Code |
No. of cores& Nominal
Conductor Cross Sectional
Area
No.×mm² |
Nominal Diameter
of Strands
mm |
Nominal
Insulation
Thickness
mm |
Nominal
Overall
Diameter
mm |
Nominal
Weight
kg/km |
| FRA-SW-0.75SU-1G1 |
1×1.0 |
32/0.2 |
0.8 |
3.9 |
28 |
| FRA-SW-0.75SU-1G1.5 |
1×1.5 |
30/0.25 |
0.8 |
4.2 |
34 |
| FRA-SW-0.75SU-1G2.5 |
1×2.5 |
50/0.25 |
0.8 |
4.6 |
41 |
| FRA-SW-0.75SU-1G4 |
1×4.0 |
56/0.3 |
0.8 |
5.2 |
64 |
| FRA-SW-0.75SU-1G6 |
1×6.0 |
84/0.3 |
0.9 |
6.4 |
93 |
| FRA-SW-0.75SU-1G10 |
1×10.0 |
80/0.4 |
0.9 |
7.5 |
141 |
| FRA-SW-0.75SU-1G16 |
1×16.0 |
126/0.4 |
1.1 |
8.6 |
203 |