4GKW-AXplus-DW 1.8/3KV Dual Wall Single Core
Applications :
4GKW-AXplus-DW 1.8/3KV Dual Wall Single Cor power and control cable designed for protected, fixed
installation inside and outside railway vehicles for connecting fixed and moving parts in direct current and
alternating voltage technology,especially converter technology.
Standards :
EN45545-2
BS 6853 -1a
NFF 16-101 F0
Construction :
Conductors : Circular Class 5 stranded tinned copper to IEC60228/VDE 0295.
Insulation1 : Electron beam crosslinkable LSZH compound.
Insulation2 : Electron beam crosslinkable LSZH compound.
Electrical Characteristics at 20 °C :
-
| Nominal Conductor Cross Section |
mm² |
1.0 |
1.5 |
2.5 |
4.0 |
6.0 |
10 |
16 |
25 |
35 |
50 |
| Maximum Conductor Resistance |
Ω/km |
20.0 |
13.7 |
8.21 |
5.09 |
3.39 |
1.95 |
1.24 |
0.795 |
0.565 |
0.393 |
| Voltage Rating |
KV |
1.8/3.0 |
-
| Nominal Conductor Cross Section |
mm² |
70 |
95 |
120 |
150 |
185 |
240 |
300 |
400 |
| Maximum Conductor Resistance |
Ω/km |
0.277 |
0.21 |
0.164 |
0.132 |
0.108 |
0.0817 |
0.0654 |
0.0495 |
| Voltage Rating |
KV |
1.8/3.0 |
Mechanical and Thermal Properties :
Minimum Bending Radius : 4xOD (Static);
6xOD (Flexing).
Temperature Range : -60℃ ~+120℃ (Static);
-40℃ ~+90℃ (Flexing).
Short Circuit Temperature : +280℃.
Dimensions and Weight :
No. of cores& Nominal
Conductor Cross
Sectional Area
No.×mm² |
Number and Nominal Diameter of Strands
No./mm |
Nominal Insulation Thickness
mm |
Nominal Overall
Diameter
mm |
Nominal Weight
kg/km |
| 1×1.0 |
32/0.20 |
0.7 |
2.8 |
17 |
| 1×1.5 |
30/0.25 |
0.8 |
3.2 |
23 |
| 1×2.0 |
32/0.20 |
0.9 |
3.55 |
28 |
| 1×2.5 |
50/0.25 |
0.9 |
3.70 |
34 |
| 1×4.0 |
56/0.30 |
1.0 |
4.45 |
53 |
| 1×6.0 |
84/0.30 |
1.1 |
5.05 |
74 |
| 1×10 |
80/0.40 |
1.2 |
6.35 |
118 |
| 1×16 |
126/0.40 |
1.5 |
8.3 |
180 |
| 1×25 |
196/0.40 |
1.8 |
10.2 |
274 |
| 1×35 |
276/0.40 |
2.0 |
11.4 |
379 |
| 1×50 |
396/0.40 |
2.2 |
13.6 |
550 |
| 1×70 |
360/0.50 |
2.1 |
15.6 |
730 |
| 1×95 |
475/0.50 |
2.3 |
17.3 |
940 |
| 1×120 |
608/0.50 |
2.4 |
19.6 |
1180 |
| 1×150 |
756/0.50 |
2.6 |
21.9 |
1510 |
| 1×185 |
925/0.50 |
2.8 |
23.8 |
1802 |
| 1×240 |
1221/0.50 |
2.9 |
26.8 |
2290 |
| 1×300 |
1525/0.50 |
3.0 |
29.7 |
2928 |
| 1×400 |
2013/0.50 |
3.4 |
35.8 |
4040 |
NF C32-070-2.1(C2)
IEC 60332-1/EN 50265-2-1 |
NF C32-070-2.2(C1)
IEC 60332-3/EN50266 |
IEC 60754-1/NF C20-454
EN 50267-2-1 |
IEC 61034/NFC20-902
EN 50268/NF C32-073 |
EN 50267-2-2/NF C32-074
IEC 60754-2/NF C20-453 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information