Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Cables for Oil Industry

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)
Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Shipboard Cables(JIS)
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Power Cables 

Power Cables

15-25kV XLPE-PVC Sheathed Unarmoured Power Cable 100 Levels

100% Insulation Levels (single conductor)

Conductor

Insulation
thickness

( mm )

Sheath
thickness

( mm )

Overall Dia.
approx.

( mm )

AC Test
voltage

( kV / 5 min )

Cable weight
approx.

( kg / km )

Size

(AWG or MCM)

Construction

( No. / mm )

Outside Dia.

( mm )

1
1/0
2/0
3/0
4/0

19/1.69
C.C.
C.C.
C.C.
C.C.

8.43
8.53
9.55
10.74
12.07

6.60
6.60
6.60
6.60
6.60

2.03
2.03
2.03
2.03
2.03

30.6
30.7
31.7
32.9
34.2

38
38
38
38
38

1229
1331
1499
1706
1961

250
300
350
400
500

C.C.
C.C.
C.C.
C.C.
C.C.

13.21
14.48
15.65
16.74
18.69

6.60
6.60
6.60
6.60
6.60

2.03
2.03
2.03
2.03
2.03

35.3
36.6
37.8
38.9
40.9

38
38
38
38
38

2187
2465
2739
3019
3559

550
750
1000

C.C.
C.C.
C.C.

20.65
23.06
26.92

6.60
6.60
6.60

2.79
2.79
2.79

44.5
47.0
50.8

38
38
38

4305
5108
6444

100% Insulation Levels (Three conductor)

Conductor

Insulation
thickness

( mm )

Sheath
thickness

( mm )

Overall Dia.
approx.

( mm )

AC Test
voltage

( kV / 5 min )

Cable weight
approx.

( kg / km )

Size

(AWG or MCM)

Construction

( No. / mm )

Outside Dia.

( mm )

1
1/0
2/0
3/0
4/0

19/1.69
C.C.
C.C.
C.C.
C.C.

8.43
8.53
9.55
10.74
12.07

6.60
6.60
6.60
6.60
6.60

2.79
2.79
2.79
2.79
3.56

62.3
62.5
64.7
67.2
71.8

38
38
38
38
38

4117
4425
4975
5646
6765

250
300
350
400

C.C.
C.C.
C.C.
C.C.

13.21
14.48
15.65
16.74

6.60
6.60
6.60
6.60

3.56
3.56
3.56
3.56

74.2
77.0
79.5
81.8

38
38
38
38

7501
8396
9236
10193

133% Insulation Levels (single conductor)

Conductor

Insulation
thickness

( mm )

Sheath
thickness

( mm )

Overall Dia.
approx.

( mm )

AC Test
voltage

( kV / 5 min )

Cable weight
approx.

( kg / km )

Size

(AWG or MCM)

Construction

( No. / mm )

Outside Dia.

( mm )

1
1/0
2/0
3/0
4/0

19/1.69
C.C.
C.C.
C.C.
C.C.

8.43
8.53
9.55
10.74
12.07

8.76
8.76
8.76
8.76
8.76

2.03
2.03
2.03
2.03
2.03

35.3
35.4
36.4
37.6
38.9

49
49
49
49
49

1492
1595
1769
1985
2249

250
300
350
400
500

C.C.
C.C.
C.C.
C.C.
C.C.

13.21
14.48
15.65
16.74
18.69

8.76
8.76
8.76
8.76
8.76

2.03
2.03
2.03
2.79
2.79

40.1
41.5
42.6
45.4
47.3

49
49
49
49
49

2484
2777
3059
3527
4081

550
750
1000

C.C.
C.C.
C.C.

20.65
23.06
26.92

8.76
8.76
8.76

2.79
2.79
2.79

49.3
51.8
55.9

49
49
49

4672
5496
6883

133% Insulation Levels (Three conductor)

Conductor

Insulation
thickness

( mm )

Sheath
thickness

( mm )

Overall Dia.
approx.

( mm )

AC Test
voltage

( kV / 5 min )

Cable weight
approx.

( kg / km )

Size

(AWG or MCM)

Construction

( No. / mm )

Outside Dia.

( mm )

1
1/0
2/0
3/0
4/0

19/1.69
C.C.
C.C.
C.C.
C.C.

8.43
8.53
9.55
10.74
12.07

8.76
8.76
8.76
8.76
8.76

3.56
3.56
3.56
3.56
3.56

74.2
74.4
76.6
79.2
82.0

49
49
49
49
49

5396
5707
6287
6993
7875

250
300
350
400

C.C.
C.C.
C.C.
C.C.

13.21
14.48
15.65
16.74

8.76
8.76
8.76
8.76

3.56
3.56
3.56
3.56

84.5
87.4
89.9
92.3

49
49
49
49

8635
9604
10526
11463

* C.C.: Stranded and compacted circular.