Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Spiral Cables

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Mining Cable  

 

Mining Cable

      NTSKCGERLOEU Medium-Voltage Coal Cutter Cable

Applications

These cables are used for the connection of mobile electrical equipment inunderground mines, e.g. for coal-cutting machines,especially for the use in bretby chains with extremebending loads under low tensile stress.

Standards

VDE 0250 Part 813

Construction

Conductors: Flexible stranded tinned copper conductor.
Insulation: Heatresistant3GI3 rubber based on EPR.
Outer Conductor Layer (for 3.6/6kV): Easy strippable outer conductive layer.
Pilot Cores:Copper/steel conductor capable ofexpansion and compression with EPRrubber insulation.
Earth Conductor: Spiral of tinnedcopper wires and a conductive tape.
InnerSheath: 2 layer design, semi conductive rubber + Rubber type 5GM5.
Armour: Spiral of steel wires,embedded in the outer sheath, fiberglas tape which preventssheath exchanging.
Outer Sheath: Rubber type 5GM5, abrasion and tear resistant, oil resistant and flame retardant.

Dimensions and Weight

1.8/3 (3.6) kV

Number of Cores×Nominal Cross Section

Minimium Overall Diameter

Maximum Overall Diameter

Nominal Weight

No.×mm²

mm

mm

kg/km

3×35+3×(1.5ST+25/3)+UEL

44.0

49.0

3900

3×50+3×(1.5ST+25/3)+UEL

50.0

55.0

5100

3×70+3×(1.5ST+35/3)+UEL

52.0

56.0

6200

3×95+3×(1.5ST+50/3)+UEL

58.0

62.0

7500

3×120+3×(1.5ST+70/3)+UEL

64.0

70.0

9350

3.6/6 (7.2) kV

Number of Cores×Nominal Cross Section

Minimium Overall Diameter

Maximum Overall Diameter

Nominal Weight

No.×mm²

mm

mm

kg/km

3×35+3×(1.5ST+25/3)+UEL

49.0

54.0

5800

3×50+3×(1.5ST+25/3)+UEL

56.0

61.0

6100

3×70+3×(1.5ST+35/3)+UEL

57.0

62.0

6700

3×95+3×(1.5ST+50/3)+UEL

62.0

66.0

8000

3×120+3×(1.5ST+70/3)+UEL

67.0

71.0

10200