Home
About Us
Products
Download
Technical Lib
Contact
Enquiry
Sitemap
Links
 

Alarm & Audio & Electronic Cables

Automotive Cables
Airport Cables

Belden Equivalent Cables

Bus Cables

Coaxial Cables

Cables for Oil Industry

Control Cables

Cable Glands
Data Cable

Fiber Optic Cables

Flexible Cables

Fire Resisting Cable(Fireflex)
Fire Retardant Cable(FIRETOX)
Flame Retardant Cable (FIREGUARD)
Heat Detection Cables
High Temperature Cables
Highway Cables

Instrumentation Cables

Industrial Cables
Lan Cables
Mining Cables
Military Cables
Medium Voltage Cables
Marine Cables
Marine, OIL,GAS & Petrochemical Cables
Power Cables
Railway Cables

Robotics

Rolling Stock Cables
Rubber & Crane Cables
Security Cables
Special Cables
Shipboard Cables(JIS)
Spiral Cables
Submarine Cables
Submersible Pump Cables for Oil Industry

Telephone Cables

Thermocouple Cables

Undersea Cables

Windmill Cable

Other Cables

BS 5308 Cable

BS 5467 Cable

BS 6724 Cable

BS 6346 Cable

BS 7211 Cable

IEC 60502-1 Cable
 

 
 
  Mining Cable  

View PDF  
View Word

Mining Cable

         Type W Single Conductor Portable Power Cable 2kV

Applications:

These cables are designed for use on electric mining locomotives and other mobile equipment of the gathering-reel type, where the cable must withstand constant flexing and reeling.

Standards:

ICEA S-75-381/NEMA WC 58

ASTM B 172ASTM B 33

CAN/CSA C22.2 No.96

Construction:

  • Conductors: Stranded annealed tinned copper conductor.
  • Insulation:EPR.
  • Reinforcement: A layer of polyester braid, applied between the insulation and sheath for mechanical strength.
  • Sheath: Chlorinated Polyethylene(CPE), black. Other sheath materials can be offered as an option.

Options:

Other jacket materials such as CSP/PCP/NBR/PVC are available upon reques.

Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties:

Minimum Bending Radius: 6×OD
Maximum Operating Temperature: +90℃

Dimensions and Weight:

Construction

No. of Strands

Nominal Insulation Thickness

Nominal Overall Diameter

Nominal Weight

Ampacity

No. of cores×AWG/kcmil

 

inch

mm

inch

mm

lbs/kft

kg/km

A

1×8

133

0.060

1.5

0.44

11.2

150

223

83

1×6

168

0.060

1.5

0.51

13.0

205

305

109

1×4

259

0.060

1.5

0.57

14.5

280

417

145

1×3

329

0.060

1.5

0.63

16.0

350

521

167

1×2

259

0.060

1.5

0.66

16.8

370

550

192

1×1

329

0.080

2.0

0.74

18.8

500

744

223

1×1/0

259

0.080

2.0

0.77

19.6

550

818

258

1×2/0

329

0.080

2.0

0.82

20.1

660

982

298

1×3/0

427

0.080

2.0

0.87

22.1

830

1235

345

1×4/0

532

0.080

2.0

0.93

23.6

950

1413

400

1×250

608

0.095

2.4

1.03

26.2

1240

1845

445

1×300

741

0.095

2.4

1.09

27.7

1400

2083

500

1×350

855

0.095

2.4

1.15

29.2

1480

2202

552

1×500

1221

0.095

2.4

1.31

33.3

2140

3184

695

Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381