Mining Cable
Type W Type G Type G-GC more

Mining Cable

Type SHD-CGC Three-Conductor Portable Power Cable 5kV

Applications

Type SHD-CGC Three-Conductor Portable Power Cables are designed for applications such as longwall

shearers, continuous miners, loaders, drills, conveyors, pumps, and other mobile equipment requiring grounding

conductors, where a ground check conductor, and metallic shielding are required.

Standards

ICEA S-75-381/NEMA WC 58

ASTM B 172

ASTM B 33

CAN/CSA C22.2 No. 96

Construction

Type SHD-CGC Three-Conductor Portable Power Cable 5kV

Conductors: Stranded annealed tinned copper conductor.

Conductor Shield:Semi-conducting layer.

Insulation:EPR.

Insulation Shield:Non-conducting tape + Tinned copper/textile braid.

Ground Check Conductor:Tinned copper with a yellow insulation, located in the center of the cable.

Grounding Conductor:Tinned copper conductor.

Sheath: Reinforced extra-heavy-duty Chlorinated Polyethylene(CPE), black. Other sheath materials can be

offered as an option.

Options:

Other jacket materials such as CSP/PCP/NBR/PVC are available upon request.

Two-layer jacket with reinforcing fibre between the two layers can be offered as an option.

Mechanical and Thermal Properties

Minimum Bending Radius: 6×OD

Maximum Operating Temperature: +90℃

Dimensions and Weight:

Construction No. of Strands Grounding Conductor Size Ground Check Conductor Size Nominal Insulation Thickness Nominal Sheath Thickness Nominal Overall Diameter Nominal Weight Ampacity
No. of cores×AWG/kcmil - AWG/kcmil AWG/kcmil inch mm inch mm inch mm lbs/kft kg/km A
3×2/0 323 5 16 0.11 2.8 0.220 5.6 2.20 55.9 3716 5529 243
3×3/0 418 4 16 0.11 2.8 0.235 6.0 2.36 59.9 4130 6145 279
3×4/0 532 3 16 0.11 2.8 0.235 6.0 2.50 63.5 5190 7722 321
3×350 888 1 16 0.12 3.0 0.265 6.7 2.95 74.9 7571 11264 435

Ampacity-Based on a conductor temperature of 90℃ and an ambient air temperature of 40℃, per ICEA S-75-381.