Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Marine Cable

P7 or P7/P14 BFOU 6/10kV

Applications :

Standards :

IEC 60092-354

IEC 60092-360

IEC 60332-1

IEC 60331-21

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606

BS 6883&BS7917 Offshore & Marine cablesBS 6883&BS7917 Offshore & Marine cables

Construction :

Conductors : Circular tinned annealed stranded compacted copper to IEC 60228 class 2.

Conductor Screen : Semi conducting material.

Insulation : Mica tape + Halogen free EPR.

Insulation Screen : Semi conducting material and tinned copper wire braid.

Bedding : Halogen free compound.

Armour : Tinned copper wire braid.

Outer Sheath : Halogen free thermosetting compound, SHF2 (for TYPE P7), or halogen free mud resistant

thermosetting compound, SHF MUD (for TYPE P7/P14), coloured red.

Electrical Characteristics :

 

Ambient Temperature Correction Factors :

Mechanical and Thermal Properties :

Bending Radius :15×OD (during installation); 9×OD (fixed installed).

Temperature Range : -20℃ ~ +90℃.

Dimensions and Weight :

Construction No. of cores×Cross section
mm²
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
Inner Outer
1×16 3.4 1.0 1.6 25.6 990
1×25 3.4 1.0 1.7 27.1 1150
1×35 3.4 1.0 1.7 28.5 1320
1×50 3.4 1.0 1.8 29.9 1500
1×70 3.4 1.0 1.8 31.9 1810
1×95 3.4 1.0 1.9 34.0 2160
1×120 3.4 1.2 2.0 36.1 2610
1×150 3.4 1.2 2.1 38.1 2990
1×185 3.4 1.2 2.2 39.9 3440
1×240 3.4 1.2 2.3 43.1 4180
1×300 3.4 1.2 2.4 45.9 4930
1×400 3.4 1.4 2.5 49.0 5900
1×500 3.4 1.4 2.6 52.5 7070
1×630 3.4 1.4 2.8 57.0 8690
3×16 3.4 1.4 2.4 50.2 3780
3×25 3.4 1.4 2.6 53.2 4380
3×35 3.4 1.4 2.7 56.4 5040
3×50 3.4 1.4 2.8 59.3 5740
3×70 3.4 1.6 2.9 63.7 6900
3×95 3.4 1.6 3.1 68.4 8270
3×120 3.4 1.6 3.2 72.1 9470
3×150 3.4 1.6 3.4 76.0 10800
3×185 3.4 1.8 3.5 80.8 12370
3×240 3.4 1.8 3.8 88.2 15040
3×300 3.4 2.0 3.9 94.0 17450

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information