Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Water Blocked

P2 or P2/P9 RFOU/TFOU 3.6/6KV

Applications

Marine cables are partially water blocked, flame retardant, low smoke, halogen free and mud resistant, used for

fixed installation for medium voltage power.

Standards

 

Water Blocked P2 or P2/P9 RFOU/TFOU 3.6/6KV

Construction

Electrical Characteristics Ambient Temperature Correction Factors Mechanical and Thermal Properties

Bending Radius :15×OD (during installation); 9×OD (fixed installed).

Temperature Range : -20℃ ~ +90℃

Dimensions and Weight

Construction No. of cores×Cross section

mm²

Nominal Insulation Thickness

mm

Nominal BeddingThickness

mm

NominalInner Sheath Thickness

mm

NominalOuter Sheath Thickness

mm

Nominal Overall Diameter

mm

Nominal Weight

kg/km

1×16 2.5 1.4 1.1 1 24.8±2 819
1×25 2.5 1.5 1.1 1.2 26.4±2 1071
1×35 2.5 1.5 1.2 1.2 27.5±2 1213
1×50 2.5 1.6 1.2 1.2 28.7±2 1386
1×70 2.5 1.6 1.3 1.2 30.6±2 1675
1×95 2.5 1.7 1.3 1.4 32.8±2 2000
1×120 2.5 1.8 1.4 1.4 34.6±2 2347
1×150 2.5 1.8 1.4 1.4 36.3±2 2678
1×185 2.5 1.9 1.5 1.4 38.0±2 3166
1×240 2.6 2 1.5 1.6 42.0±2 3911
1×300 2.8 2.1 1.6 1.6 45.5±2 4856
1×400 3 2.2 1.7 1.6 49.8±2 5691
1×500 3.2 2.4 1.8 1.6 54.0±2 6941
1×630 3.2 2.5 1.9 1.6 58.3±2 8579
3×16 2.5 2.2 1.6 1 46.9±2 3077
3×25 2.5 2.3 1.7 1.2 47.8±2 3560
3×35 2.5 2.4 1.8 1.2 50.0±2 4011
3×50 2.5 2.5 1.9 1.2 53.3±2 4720
3×70 2.5 2.7 2 1.2 57.2±2 5864
3×95 2.5 2.8 2.1 1.4 61.7±2 7103
3×120 2.5 3 2.2 1.4 66.3±2 8573
3×150 2.5 3.1 2.3 1.4 70.2±2 9970
3×185 2.5 3.3 2.4 1.4 78.6±2 11193
3×240 2.6 3.5 2.5 1.6 85.5±2 12243
3×300 2.8 3.8 2.7 1.6 92.5±2 13587