Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

Marine Cable

F103 (Formerly F5) QFCB

Applications :

F103 (Formerly F5) QFCB optical fibre cables are flame retardant, low smoke, halogen free and fire resistant,

used for communication and emergency systems that need to be operational during fire.

Standards :

IEC 60794

IEC 60811-2-1

IIEC 60331-25

IEC 60332-3-24

IEC 60332-3-22

IEC 60754-1,2

IEC 61034-1,2

NEK 606:2016

BS 6883&BS7917 Offshore & Marine cablesBS 6883&BS7917 Offshore & Marine cables

Construction :

Fibre Element: Loose tube core design with fire barrier.

Central Strength Element: Steel wire or fibre reinforced plastic (FRP).

Overall Fire Barrier(optional)

Bedding: Halogen free and flame retardant thermoplastic compound.

Armour: Galvanized steel wire braid.

Outer Sheath1: Halogen free and flame retardant, UV-stabilized, thermoplastic compound, SHF1.

Outer Sheath2: Mud resistant and halogen-free thermoplastic compound.

Electrical Characteristics :

Mechanical and Thermal Properties :

Bending Radius : 20×OD (during installation); 10×OD (fixed installed).

Dimensions and Weight :

No. of Fibres Construction No. of tubes×No. of fibres in each tube Number of Fillers Nominal Loose Tube Diameter
mm
Nominal Overall Diameter
mm
Nominal Weight
kg/km
2 1×2 5 2.2 15.0 290
4 1×4 5 2.2 15.0 290
6 3×2 3 2.2 15.0 290
8 2×4 4 2.2 15.0 290
10 5×2 1 2.2 15.0 290
12 3×4 3 2.2 15.0 290
16 4×4 2 2.2 15.0 290
20 5×4 1 2.2 15.0 290
24 6×4 0 2.2 15.0 290
32 4×8 2 2.2 15.0 290
40 5×8 1 2.2 15.0 290
48 6×8 0 2.2 15.0 290