| IEC60092 Offshore & Marine Cables | |||
| MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
CAN BUS CABLES 120Ω
Application
CAN BUS CABLES 120Ω are dedicated to the shipbuilding industry.
Standards
IEC 60092-350/360/352/353/370 /376
IEC 60332-1-2
IEC 60332-3-22
IEC 60754-1/2
IEC 61034
Construction

Conductors: Stranded tinned copper 21AWG.
Insulation: Foam skin PP.
Inner Sheath: Thermoplastic copolymer (FRNC).
Overall Screen1: Aluminium/polyester tape.
Overall Screen2: Tinned copper braid.
Outer Sheath: LSOH (SHF1).
Core Identification
Pair 1: Blue, Red
Pair 2: Brown, Green
Electrical Properties
| Characteristic Impedance | Ω | 120 ± 18 | |
|---|---|---|---|
| Mutual Capacitance @1KHz | nF/km | 36 | |
| Insulation Resistance | GΩ.km | 5 | |
| 1 pair | 2 pair | ||
| Attenuation @0.1MHz | dB/100m | 0.65 | 0.3 |
| Attenuation @1MHz | dB/100m | 1.9 | 1.1 |
| Attenuation @5MHz | dB/100m | 4.3 | 2.8 |
| Attenuation @10MHz | dB/100m | 8.1 | 3.9 |
| Attenuation @20MHz | dB/100m | 10.5 | 5.7 |
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 10×OD
Temperature Range: -30℃ ~ +80℃
Dimensions and Weight
| Part No. | Construction No. of elements×No. of cores in element×Cross section mm² |
Core Diameter mm | Nominal Overall Diameter mm |
Nominal Weight kg/km |
|---|---|---|---|---|
| MLN-09YSH(ST)CH-1×2×21A | 1×2×21 AWG | 2.4 | 7.7 | 79 |
| MLN-09YSH(ST)CH-2×2×21A | 2×2×21 AWG | 2.2 | 8.4 | 90 |
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information