IEC60092 Offshore & Marine Cables
MariTox Marine Flame Retardant Medium Voltage Cables MariTox Marine Flame Retardant Power & Control Cables MariFlex Marine Fire Resistant Power & Control Cables other

MRE-M3GCH

150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair)


Application

150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation

& Control Cables (Multipair) are used on board of ships in all locations for fixed installations complying with IEC

standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame

retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial

vessels.

Standards

DIN 89159

IEC 60092-360/375

IEC 60331-21

IEC 60332-1

IEC 60332-3-22

IEC 60754-1/2

IEC 61034

Construction

150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair)

Conductors: Stranded copper conductor.

Insulation: Mica tape + HEPR.

Cabling Element: Pair.

Armour: Copper wire braid.

Outer Sheath: LSOH (SHF1).

Core Identification

Pair: White/blue with printed pair number and core number

Mechanical and Thermal Properties

Bending Radius for Fixed Installations: 6×OD

Temperature Range: -30℃ ~ +75℃

Dimensions and Weight

Part No. Construction
No. of elements×No. of cores in element×Cross section
mm²
Nominal Insulation Thickness
mm
Nominal Sheath Thickness
mm
Nominal Overall
Diameter mm
Nominal Weight
kg/km
MRE-M3GCH-1P0.75 1×2×0.75 0.5 1.2 10.5 110
MRE-M3GCH-2P0.75 2×2×0.75* 0.5 1.3 11.0 150
MRE-M3GCH-4P0.75 4×2×0.75 0.5 1.4 16.0 270
MRE-M3GCH-7P0.75 7×2×0.75 0.5 1.8 19.0 400
MRE-M3GCH-10P0.75 10×2×0.75 0.5 1.9 22.0 560
MRE-M3GCH-14P0.75 14×2×0.75 0.5 2.0 27.0 740
MRE-M3GCH-19P0.75 19×2×0.75 0.5 2.1 29.0 930
MRE-M3GCH-24P0.75 24×2×0.75 0.5 2.2 31.0 1110

*: 2 pairs are assembled as a quad.

Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information