| IEC60092 Offshore & Marine Cables | |||
| MariTox Marine Flame Retardant Medium Voltage Cables | MariTox Marine Flame Retardant Power & Control Cables | MariFlex Marine Fire Resistant Power & Control Cables | other |
MRE-M3GCH
150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation & Control Cables (Multipair)
Application
150/250V Mica Tape + HEPR Insulated, LSOH (SHF1) Sheathed, Armoured Fire Resistant Instrumentation
& Control Cables (Multipair) are used on board of ships in all locations for fixed installations complying with IEC
standards 60092-352 in safety circuit, where fire resistance is required. These cables are fire resistant, flame
retardant, low smoke & halogen free, suitable for installations on passenger ships, as on other commercial
vessels.
Standards
DIN 89159
IEC 60092-360/375
IEC 60331-21
IEC 60332-1
IEC 60332-3-22
IEC 60754-1/2
IEC 61034
Construction

Conductors: Stranded copper conductor.
Insulation: Mica tape + HEPR.
Cabling Element: Pair.
Armour: Copper wire braid.
Outer Sheath: LSOH (SHF1).
Core Identification
Pair: White/blue with printed pair number and core number
Mechanical and Thermal Properties
Bending Radius for Fixed Installations: 6×OD
Temperature Range: -30℃ ~ +75℃
Dimensions and Weight
| Part No. | Construction No. of elements×No. of cores in element×Cross section mm² |
Nominal Insulation Thickness mm |
Nominal Sheath Thickness mm |
Nominal Overall Diameter mm |
Nominal Weight kg/km |
|---|---|---|---|---|---|
| MRE-M3GCH-1P0.75 | 1×2×0.75 | 0.5 | 1.2 | 10.5 | 110 |
| MRE-M3GCH-2P0.75 | 2×2×0.75* | 0.5 | 1.3 | 11.0 | 150 |
| MRE-M3GCH-4P0.75 | 4×2×0.75 | 0.5 | 1.4 | 16.0 | 270 |
| MRE-M3GCH-7P0.75 | 7×2×0.75 | 0.5 | 1.8 | 19.0 | 400 |
| MRE-M3GCH-10P0.75 | 10×2×0.75 | 0.5 | 1.9 | 22.0 | 560 |
| MRE-M3GCH-14P0.75 | 14×2×0.75 | 0.5 | 2.0 | 27.0 | 740 |
| MRE-M3GCH-19P0.75 | 19×2×0.75 | 0.5 | 2.1 | 29.0 | 930 |
| MRE-M3GCH-24P0.75 | 24×2×0.75 | 0.5 | 2.2 | 31.0 | 1110 |
*: 2 pairs are assembled as a quad.
Note: The parameters listed above are nominal values as per cable standards. Actual values may vary due to material and manufacturing process variations. For precise specifications or customized requirements, please contact us for further information