Inicio
Quiénes somos
Producto
Descargar
Biblioteca Técnica
Contacto
Enquiry
Mapa del Sitio
Enlaces
 

Alarmar y Cable Audio y Electrónico

Equivalente de Cable Belden

Cable coaxial 

Cables de control

Cables de Fibra óptica

Flexible Cable

Instrumentación Cables

Lan Cables
Cables de Potencia
Cables de ferrocarril

Robótica

Cables de material rodante
Caucho y Cable Crane
Cables de Seguridad

Cables telefónicos

Aeropuerto Cables

Cables de bus

Cable Glands

Cable de datos

Cable de detección de celo
Cables de alta temperatura
Cables autopista
Marine, Petróleo, Gas y Petroquímica Cables
Cables Especiales
Espiral Cables
Cables de Termopar
Mining Cables
Industrial Cables
Undersea Cables
Military Cables
Marine Cables
Hoop-Up Wire
Other Cables
     
  Indoor tight buffer fiber optic cable  
Indoor Used Tight Buffered Fiber
Optical Cable
outdoor multi loose tube fiber optic cable
Outdoor Used Multi Loose Tube
Fiber Optical Cable
 
  Industrial Cables  

Industrial Cables

H07V-K

Application and Description

These are not suitable to be installed for laying in tubes, under and surface mounting of plaster and also
in closed installation conduits. These are not allowed to install for direct laying on cable trays, channel or
tanks. These types are permitted for the inner wiring of equipment, distributor and switchboards and also for
protective laying to the lightings with a nominal voltage up to 1000 V alternating current or up to 750 V direct
current against earth.

Standard and Approval

<HAR> HD 21.3 S3, VDE-0281 Part-3, CEI 20-20, CEI20-52,
CE Low Voltage Directive 73/23/EEC and 93/68/EEC, ROHS compliant

Cable Construction

- Fine bare copper strands
- Strands to VDE-0295 Class-5, IEC 60228 Class-5
- Special PVC TI1 core insulation
- Cores to VDE-0293 colors on chart

Technical Characteristics

- Working voltage: 450/750V
- Test voltage: 2500 volts
- Flexing bending radius: 12.5 x Ø
- Static bending radius: 12.5 x Ø
- Flexing temperature: -5º C to +70º C
- Static temperature: -30º C to +80º C
-Short circuit temperature: +160º C
- Flame retardant: IEC 60332.1
- Insulation resistance: 10 MΩ x km

          

Cable Parameter

AWG
No. of Cores x Nominal Cross Sectional Area # x mm²
Nominal Thickness of Insulation mm
Nominal Overall Diameter
mm
Nominal Copper Weight kg/Km
Nominal Weight kg/Km
1 x 1.5
0,7
3.1
14.4
20
14(50/30)
1 x 2.5
0,8
3.6
24.0
31
12(56/28)
1 x 4
0,8
4.3
38.0
48
10(84/28)
1 x 6
0,8
4.9
58.0
69
8(80/26)
1 x 10
1,0
6.4
96.0
121
6(128/26)
1 x 16
1,0
8.1
154.0
211
4 (200/26)
1 x 25
1,2
9.8
240
303
2 (280/26)
1 x 35
1,2
11.1
336
417
1 (400/26)
1 x 50
1,4
13.1
480
539
2/0 (356/24)
1 x 70
1,4
15.5
672
730
3/0 (485/24)
1 x 95
1,6
17.2
912
900
4/0 (614/24)
1 x 120
1,6
19.7
1152
1135
1 x 150
1,8
21.3
1440
1410
350 MCM (944/24)
1 x 185
2,0
23.4
1776
1845
500MCM(1225/24)
1 x 240
2,2
27.1
2304
2270